Digital Rotary Pulse Meter Capable of 50 kHz Measurements.
Visual confirmation of judgement results through display colors that switch,
between red and green.
Measures High-speed Pulses at 50 kHz.
Provides high-speed pulse measurements up to 50 kHz of rotary encoder,
or ON/OFF pulse.
signals and can perform rotating measurement of high-speed rotating objects K3HB-PPB-L2AT11 AC/DC24V PDF datasheet
K3HB-PPB-L2AT11 AC/DC24V
Note: No-voltage contacts of up to 30 Hz are supported.
Six Measurement Operations Including Rotation (rpm)/Circumferential,
Speed, Ratio, and Cumulative.
One Rotary Pulse Meter has 6 rotary pulse measurement functions to,
support a variety.
of pulse measurement applications. Select the best function for your,
application from the K3HB-PPB-L2AT11 AC/DC24V PDF datasheet.
following: Rotation (rpm)/circumferential speed/instantaneous flowrate,
(value proportional to frequency), absolute ratio, error ratio, error,
flow rate ratio, and passing.
speed (value inversely proportional to frequency).
DeviceNet models added to the series. Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA K3HB-PPB-L2AT11 AC/DC24V PDF datasheet.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Linear: current; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of wide range of pulse interval time.
Measuring, calculating and displaying the pulse interval between 2 points.
Pulse interval measurement range, maximum measurable fromTime specification: Inverse type.
Current setting range: 8 to 26 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operatioon K3HB-PPB-L2AT11 AC/DC24V datasheet PDF catalog.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K3HB-PPB-L2AT11 AC/DC24V datasheet PDF catalog. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.