Product model: K3HB-XVA-L1AT11 AC100-240
Name: Voltage and current panel meter
Brand: OMRON
Sort: PDF datasheet
File language: English
Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (S-TMR, HOLD, RESET) is equipped with.
External power 80mA DC12V.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
DeviceNet; DeviceNet:--.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC100 ~ 240V.
Digital rotating pulse meter with high speed measurement for 50kHz K3HB-XVA-L1AT11 AC100-240 PDF datasheet K3HB-XVA-L1AT11 AC100-240
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of 50kHz high speed pulse.
Rotary encoder and a variety of ON/OFF pulse signals, the most up to 50kHz of high-speed pulse measurementTime specification: Inverse type.
Current setting range: 20 to 65 A.
Operating voltage: 200/220/240 VAC K3HB-XVA-L1AT11 AC100-240 PDF datasheet.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button K3HB-XVA-L1AT11 AC100-240 PDF datasheet.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Appearance: ADR shell.
Circuit structure and open circuit mode: constant circuit contact, secondary current circuit breaker.
Rated current: AC5A.
Rated frequency: 50/60Hz (switching).
Current adjustment range: time limit elements: 3-3.5-4-4.5-5-6A, 6 shunt;
Instantaneous elements: 20-30-40-50-60A-, 6 shunt.
Action time: time limit elements: 0.25-0.5-1-2-3-4-5-6-7-8-9-10-15-30-60-120,
Minimum action value, adjust the scale of movement, 300% over current, 10s plus or minus 17%;
700% over current, 16.7s plus or minus 12%; instantaneous elements: 200% over current, 50ms.
Control power supply: do not.
Rated consumption VA:6VA.
Contact capacity: AC12V, 60A (CT secondary current) 100 times; AC20V, 100A (CT secondary current) 3 times.
Contact: AC250V, 5A, cos, DC30V, 5A, =1; Cos =1.
Automatic experiment: there.
Display: measurement display, resolution. Display resolution 9.9A the following is 0.1A, more than 1A.
Display range: 2.0A-20A, output display, trip (R phase and T phase) manual reset,
Instant manual reset type.
Excitation surge current suppression (fuzzy inference): the relative basic wave component second harmonic components of the containing rate is higher than 5%,
In the above area, the excitation surge current can be suppressed.
Quality: about 1.2kg.
External: Mount Searl N1.5.
Digital over current K2CA-H type,
Using the advanced technology of fuzzy inference to make the protection and coordinationn of digital DCR K3HB-XVA-L1AT11 AC100-240 datasheet PDF catalog.
And automatic testing machine, so that the relay test is easy.
By using fuzzy inference, the excitation surge current is reduced.
Improve reliability by monitoring function at any timme K3HB-XVA-L1AT11 AC100-240 datasheet PDF catalog.
With 1 sets of three-phase protection.
To save space, save wiring to make contribution.
Based on the DIN standard size, small depth is only 88.5mm.