LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Catalog Download
OMRON K8AC-H21CN-FLK datasheet PDF catalog K8AC-H21CN-FLK PDF datasheet
Product model: K8AC-H21CN-FLK
Name: Digital Heater Element Burnout Detector
Brand: OMRON
Sort: PDF datasheet
File language: English
Type of input: platinum resistance / thermocouple input.
Event input terminal 4 points (TIMING, S-TIM, HOLD, RESET) is equipped with.
Transistor: -; NPN open collector (HH, H, PASS, L, LL).
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24.
Temperature indicator and measurement of various processes K8AC-H21CN-FLK PDF datasheet.
Action determine the color, can switch the green / Red 2 kinds of color display K8AC-H21CN-FLK
High speed sampling of 50 /s (20ms).
0.01 degree: platinum temperature resistance body Pt100 high resolution.
Thermocouple sensor (full range) to support the resolution of 0.1.
The temperature input compensation can be easily set by 2 points.
DeviInput type: DC voltage input type.
Output type: relay contact; 1c H; PASS, L: each 1c K8AC-H21CN-FLK PDF datasheet.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) some models are not equipped with depth.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table.
Action determine the color, can switch the green / Red 2 kinds of color display K8AC-H21CN-FLK PDF datasheet.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
Series of DeviceNet type.
Depth (panelModel: UFR (95L).
Protection of distributed power supply connection to power system,
The relay is smaller, and the protection unit is more enriched.
Waste heat generation system improve the comprehensive energy efficiency and the use of natural,
Energy of wind power generation, the spread of power is becoming more and more popular.
This relay is used to detect the internal fault of the user in the distributed power supply,
Power line accident of distributed power supply and relay protection system.
The relay can be meet in Japan (system connected instant points specified in the standard model),
Function, can be through more than 20 kinds of products to establish the best protection system.
Can also correspond to the generator and the electric side / internal tributaries.
Unit with 2 relay elements K8AC-H21CN-FLK datasheet PDF catalog.
In each unit, the variable action time circuit is hidden, so that the coordination design is more convenient.
All aircraft equipped with a locking relay terminal.
DSR can correctly determiine the direction of the sudden drop in the voltage to 0 of the short-circuit accident K8AC-H21CN-FLK datasheet PDF catalog.
2 stage cross terminal stand with cover with convenient wiring.
Related products