Time specification: Instantaneous type.
Current setting range: 2 to 8 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage K8AC-H23PC-FLK Communications Manual.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase
K8AC-H23PC-FLK
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K8AC-H23PC-FLK Communications Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Three-phase Phase-sequence Phase-loss.
Relay Using Voltage Detection Method.
Fixed phase Asymmetry monitoring.
Prevents reverse motor rotation due to incorrect wiring K8AC-H23PC-FLK Communications Manual.
Distinguishes between positive phases, reversed phases, and phase,
loss when power is turned ON.
Voltage detection method enables application for any load current.
One SPDT output relay, 6 A at 250 VAC (resistive load).
Output status can be monitored using LED indicator. Ideal for 3-phase Voltage Asymmetry.
Monitoring for Industrial Facilities and Equipment.
Greater resistance to inverter noise.
Monitor voltage asymmetry, phase sequence, and phase,
loss for three-phase 3-wire or 4-wire power supplies with just one Unit.
Switch setting for 3-phase 3-wire or 3-phase 4-wire power supply.
One SPDT output relay, 5 A at 250 VAC (resistive load).
World-wide power specifications supported by one Unit (switchable).
Relay status can be monitored using LED indicator. Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Relay contact: H; PASS1c, L, each 1c.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
Measuremment of 2 points through the speed, time, or cycle of the digital time interval table K8AC-H23PC-FLK Manual.
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of wide range of pulse interval time.
Measuuring, calculating and displaying the pulse interval between 2 points K8AC-H23PC-FLK Manual.
Pulse interval measurement range, the maximum can be measured from 10ms to 3200s