LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Catalog Download
OMRON SRT2-OD16-1 datasheet PDF catalog SRT2-OD16-1 PDF datasheet
Product model: SRT2-OD16-1
Name: Transistor Remote I/O Terminals
Brand: OMRON
Sort: PDF datasheet
File language: English
Control power supply voltage: 100/110 VDC.
Input: DC or AC (selectable); input voltage range: 10 to 300 V: Operating mode,
ON-delay; OFF-delay; Startup lock.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V SRT2-OD16-1 PDF datasheet.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL) SRT2-OD16-1
Detect three-phase AC current for under and/or overcur,
rent using current converter.
Available in 7 supply voltage configurations.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verse current detection SRT2-OD16-1 PDF datasheet.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@). Power ratings: 30 W.
Input voltage: Single phase, 100 to 240 VAC, 90 to 350 VDC.
Output Voltage: 24 V.
Output current: 1.3 A.
Boost Current: 1.56 A.
Reliable and Easy Operation-Worldwide Power Supply.
Resistant in tough environments SRT2-OD16-1 PDF datasheet.
Easy and fast installation.
The most compact class on the market.
Universal input for worldwide applications:
100 to 240 VAC (85 to 264 VAC).
DC input can be available: 90 to 350 VDC.
Possible for 2-phase input usage.
Wide operation temperature range: –40 to 70 °C.
Power Boost function at 120%.
Safety standards:
UL508/60950-1, CSA C22.2 No. 107.1/60950-1.
EN50178, EN60950-1.
Lloyd’s standards, EN60204-1 PELV.
Safety of Power Transformers: EN61558-2-16.
ANSI/ISA 12.12.01 (excluding 480-W models).
CSA C22.2 No.213 (excluding 480-W models).
15-W,30-W, and 60-W models conform to.
UL Class 2 output Standards.
EMS: EN 61204-3.
EMI: EN 61204-3 Class B.
Three years Warranty *1. Power ratings: 120 W.
Input voltage: 100 to 240 VAC(allowable range: 85 to 264 VAC or 80 to 370 VDC*3).
Output voltage: 24 V.
Output current: 5 A.
UL Class 2 Output standards: --.
Model number(screwless terminal block).
60/90/120/180/240/480-W Models.
New Models with Indication.
Monitor and Simple Functions for.
Easy System Commissioning.
New 90-W models with indication monitor that.
conform to UL Class 2 Output standards.
New models with screwless terminal blocks and,
indication monitor SRT2-OD16-1 datasheet PDF catalog.
Status displayed on 3-digit, 7-segment display.
Safety standards: UL 508/60950-1,
CSA C22.2 No. 107.1/60950-1,
EN 50178 (= VDE 0160), EN 60950-1 ((= VDE 0805 Teil 1) SRT2-OD16-1 datasheet PDF catalog.
Input conditions: DC input is also possible from 80 to 370 VDC.
(Not compliant with EC Directives and other safety standards.)
Related products
OMRON
Expansion Units
XWT-OD16-1
OMRON Expansion Units XWT-OD16-1
Name: Expansion Units. Specifications:
OMRON
Transistor Remote I/O Terminals
SRT2-OD16-1
OMRON Transistor Remote I/O Terminals SRT2-OD16-1
I/O classification: Output. Internal I/