I/O classification: Output.
Internal I/O circuit common: PNP (+ common).
I/O points: 16.
Rated voltage: 24 VDC.
I/O rated voltage: 24 VDC.
(Long-distance/High-speed Communications Selection).
(W x H x D) mm for 16-point terminals.
because the I/O terminals are insulated from the internal circuits.
DIN track mounting and screw mounting are both supported.
Specifications: Inputs; NPN (+ common); 16 inputs.
I/O connections: Sensor connector.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage:
Supplied from the communications connector.
Includes Sensor Connector That Conforms to,
Industry Standards And Can Be Used to Connect OMRON SRT2-OD16-1.
Sensors with Pre-wired Cables without Using,
Special Tools
SRT2-OD16-1
Equipped with the standard Smart Slave,
functions that provide powerful.
preventative maintenance and,
troubleshooting capabilities.
Digital I/O Terminal compatible with,
industry-standard sensor connectors.
Connect sensors easily without special tools.
Reduce time required for wiring OMRON SRT2-OD16-1.
Load short-circuit detection. Name: Three-tier Screw Terminal Block.
Specifications: Outputs; 16 outputs; NPN;
With Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction OMRON SRT2-OD16-1.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Specifications: Inputs; NPN (+ common); 16 points.
I/O connections: M3 Screw terminals.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Allows I/O Expansion with Transistor Terminals.
Wide variety of data, such as maintenance system data,
can be collected without affecting the produuctivity,
of the control system SRT2-OD16-1.
Valuable information can be collected,
and managed through the network, including information,
on the communications power supply.
voltage levels, Unit wear and tear,
and equipment operating informattion SRT2-OD16-1.
Expansion via Expansion I/O Units.
With no communications baud rate settings,
required and detachable terminal blocks,
maintenance is easier.