LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
OMRON 3G3MX2-A2007 Manual 3G3MX2-A2007 INSTRUCTION SHEET
Product model: 3G3MX2-A2007
Name: Rotary Pulse Meter
Brand: OMRON
Sort: INSTRUCTION SHEET
File language: English
Specification: three phase 400V.
Power: 2.2KW.
Maximum output voltage: three phase input voltage.
Rated voltage, frequency: three-phase power supply 380 ~ 50/60Hz, 480V.
Cooling: forced air cooling.
Weight: 1.9kg.
Open loop vector control mode of low speed and high torque, rich control function and convenient distribution management network function,
Set in one of the inverter --3G3MZ 3G3MX2-A2007 INSTRUCTION SHEET 3G3MX2-A2007
3G3MZ series inverter for the application of frequency control and development.
Humanized design and advanced management technology, as well as OMRON a simple style of modeling, feature rich style,
Combined with the latest technical needs of users, so that it has a noble lineage and the most close to the market elements 3G3MX2-A2007 INSTRUCTION SHEET.
Covers the special features of the fan pump class, open loop vector function,
Built in noise filter and a variety of network bus,
3G3MZ will be your most economical and the most perfect choice. Box protection class: plastic, IP00.
Terminal size: M5.
Line diameter: 14 square mm.
Weight: 1.6kg.
Used to reduce the noise from the power cord to the frequency converter or from the frequency converter to the power line 3G3MX2-A2007 INSTRUCTION SHEET.
Try to be close to the transducer for connection. Box protection class: plastic, IP00.
Terminal size: M4.
Line diameter: 5.5 square mm.
Weight: 0.8kg.
Used to reduce the noise from the power cord to the frequency converter or from the frequency converter to the power line.
Try to be close to the transducer for connection. Box protection class: plastic, IP00.
Terminal size: M4.
Line diameter: 2 square mm.
Weight: 0.6kg.
Used to reduce the noise from the power cord to the frequency converter or from the frequency converter to the power line.
Try to be close to the transducer for connection. Function name: 3 phase 200V.
Power: 0.75KW.
Rated output voltage: 3 phase, 200 ~ 240V (the output voltage can not exceed the input voltage).
Built in brake unit (brake resistance needs to be matched).
Weight: 1.2KG.
Dimension (w * h) 128mm *:68.
Outline dimension (deep):145.5mmm 3G3MX2-A2007 Manual.
Mechanical automation concept.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication.
Driver programming function.
Current vector control.
High starting torque: 00 3G3MX2-A2007 Manual. 5Hz up to 200%.
Safety features, in compliance with ISO13849-1:2008 EN (Cat.3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H.