LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
OMRON 3G3MX2-AB007-ZV1 Manual 3G3MX2-AB007-ZV1 Quick Reference Guide
Product model: 3G3MX2-AB007-ZV1
Name: Linear Sensor lndicator
Brand: OMRON
Sort: Quick Reference Guide
File language: English
Cable length: 3m.
A digital operator is installed in a place far away from the transducer. Specification: three phase 400V.
Power: 3.7KW.
Maximum output voltage: three phase AC380 ~ 480V (input voltage correspondence).
Rated voltage: three phase 480V ~ 50/60Hz AC380.
Weight: about 4kg.
In the inverter is equipped with the servo can play the same static torque with PG vector control function,
DeviceNet communication makes the application field more extensive 3G3MX2-AB007-ZV1 Quick Reference Guide 3G3MX2-AB007-ZV1
The high functional specifications are concentrated in the compact.
Equipped with PG vector control.
Subsequent models of 3G3RV.
CV/VT selection function.
Rich online automatic adjustment function (self learning function).
CX-Drive software 3G3MX2-AB007-ZV1 Quick Reference Guide.
DeviceNet correspondence correspondence.
Multi function input and output function.
Colorful function.
Brake transistor built-in.
Protection function. Box protection class: plastic, IP00.
Terminal size: M5.
Line diameter: 14 square mm.
Weight: 1.6kg.
Used to reduce the noise from the power cord to the frequency converter or from the frequency converter to the power line.
Try to be close to the transducer for connection 3G3MX2-AB007-ZV1 Quick Reference Guide. Applicable converter capacity: maximum 5.5KW, minimum 0.1KW.
Connected to the converter input / output cable,
Reduce the noise from the power supply line to the frequency converter or from the converter to the power line. Level: 3 phase 200V level.
Connecting resistance: 17 or more.
Internal resistance value: 120W, 20W.
In 3G3MX2 with the use of the braking resistor, can shorten the motor deceleration time.
Alarm output terminal of regenerative braking unit.
The temperature relay built-in resistance or braking resistance optional activation,
A circuit to cut off the main power supply of the frequency converter. Function name: 3 phase 200V.
Power: 7.5KW.
Rated output voltage: 3 phase, 200 ~ 240V (the output voltage can not exceed the input voltage).
Built in brake unit (brake resistance needs to be matched).
Weight: 3.4KG.
Dimension (w * h) 260mm *:140.
Outline dimension (deep):155mm.
MMechanical automation concept 3G3MX2-AB007-ZV1 Manual.
Positioning function.
The use of options.
(EtherCAT, CompoNet and DeviceNet) to realize the field bus communication.
Driver programming function.
Current vector control.
High starting torque: 00 3G3MX2-AB007-ZV1 Manual. 5Hz up to 200%.
Safety features, in compliance with ISO13849-1:2008 EN (Cat.3/PLd) and IEC60204-1 stop level 0 standard.
Frequency output up to 580H.