Name: Temperature Sensor Module.
Model: C200H-TS102.
Temperature sensor: RTD (Pt 100 Ω.)(DIN/1989 JIS).
Input points: 4 points/Unit max. (1, 2, or 4 points can be selected).One Ethernet Option Board can be mounted in either option board slot 1 or 2.
Note: Cannot be used for the CP1L-L10.Connects SYSMAC LINK Unit, Controller Link Unit to CPU Unit CJ1W-MAD42 OPERATION MANUAL.
For 1 Unit.Specification: Platinum resistance thermometer input (Pt100, JPt100),
manual operation,
ON/OFF or advanced PID control,
transistor (PNP) output, 4 loops
CJ1W-MAD42Connects to the I/O module located on the extreme right.Product name: N@@-type CPU Units with 60 I/O Points.
Specifications: Power Supply, 100 to 240 VAC; Inputs, 36; Outputs, 24;
Output type: Relay CJ1W-MAD42 OPERATION MANUAL.
Program capacity: 8K steps.
memory Data capacity: 8K words.
External powersupply(24 VDC): 0.30A.
Current consumption: 5 V, 0.21A; 24 V,0.13A.
Standards: UC1, N, L, CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection CJ1W-MAD42 OPERATION MANUAL. Name: e-CON Connector Type.
Specifications: Analog inputs;
4 inputs.
Standards: CE, UC, UC1.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. CPU Unit: CP1L-M CPU Units with 60 Points.
Specifications: CPU type, Memory capacity: 10K steps
High-speed counters: 100 kHz, 4 axes Pulse outputs:
100 kHz, 2 axes (Models with transistor outputs only);
Power supply, AC power supply; Output methodd, Transistor output (sinking);
Inputs, 36; Output, 24 CJ1W-MAD42 Manual.
Standards: UC1, N, L, CE.
High Performing Programmable Controller with Embedded Ethernet.
"CP1L-EM" and "CP1L-EL" has a standard-feature Ethernet port.
"CP1L-M" and "CCP1L-L" has a standard-feature peripheral USB port CJ1W-MAD42 Manual.
Function blocks (FB) allow you to build up modular structure and,
programming of ladder diagrams.