Unit type: CJ1 Basic I/O Units.
Product name: DC Input Units.
MIL connector; No. of words allocated, 2 word.
Current consumption: 5V, 0.09A; 24V, --.
Standards: UC1, N, L, CE.
Different Applications.
I/O memory in the CPU Unit.
CJ1W-ID233 are now available. These units can,
help to increase system throughput.
Unit type: CJ1 Basic I/O Units.
Product name: DC Input Units.
Specifications: I/O points, 8 inputs;
Input voltage and current: 12 to 24 VDC, 10 mA;
Commons, Independent contacts; External connection,
Removable terminal block; No. of words allocated, 1 word.
Current consumption: 5V, 0.09A; 24V, -- OMRON CJ1W-ID232.
Standards: UC1, N, L, CE.
A Wide Range of Basic Input,
Units for High Speed Input and,
Different Applications
CJ1W-ID232
Receive ON/OFF signals from external,
devices into the PLC System to update,
I/O memory in the CPU Unit.
New high-speed input models CJ1W-ID212 and,
CJ1W-ID233 are now available. These units can,
help to increase system throughput. Unit type: CJ1 Special I/O Units.
Product name: Analog Output Unit OMRON CJ1W-ID232.
I/O points: 4 outputs;
Signal range selection:
Set separately for each output.
Signal range, Resolution: 1 to 5V(1/10,000),
0 to 10V(1/20,000), and -10 to 10V(1/40,000).
Conversion period: 20 μs/ 1 point,
25 μs/ 2 points, 30 μs/ 3 points,
35 μs/ 4 points The Direct conver sion is provided.
Accuracy at ambient temperature of 25°C:
±0.3% of F.S OMRON CJ1W-ID232.
External connection: Removable terminal block.
External power supply: --.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.40A; 24V, --.
Standards: UC1, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Analog Input Units for converting analog input,
signals into binary data.
Analog Output Units for converting binary ,
data into analog output signals. Unit type: CJ1 Special I/O Units.
Product name: Analog Input Unit.
I/O points: 8 inputs;
Signal range selection: 1 to 5 V, 0 to 5 V,
0 to 10 V, -10 to 10 V, 4 to 20mA;
1/4,000(Settable to 1/8,000)*2 .
Conversion period: 1 ms/point,
(250 μs/point can also be set.)*2.
Accuracy at ambient temperature of 25°C:
Voltage: ±0.2% of F. S. Current: ±0.4% of F.S.
Externall connection: Removable terminal block CJ1W-ID232.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.42A; 24V, --.
Standards: UC1, N, L, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Anaalog Input Units for converting analog input,
signals into binary data CJ1W-ID232.
Analog Output Units for converting binary ,
data into analog output signals.