Model: CPM2C-TS001. 2 inputs for thermocouples I/O Interface UnitC500-DA Special I/O Unit Analog Output C500-DA103.
Output: 4 pts.
Specification: -10~+10V.Model : C500-LK203.
RS-232C/RS-422.Product name: E@@S type CPU Units with 14 I/O Points.
Specifications: Power Supply, 100 to 240 VAC; Inputs, 8;Outputs, 6;
Output type, Relay; Program capacity, 2K steps; memory Data capacity, 2K words CQM1H-ME16K System Manual
CQM1H-ME16K
External powersupply(24 VDC): --.
Current consumption: 5 V, 0.16A; 24 V,0.07A.
Standards: CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection CQM1H-ME16K System Manual. 1 axis, Pulse input. counting speed: 50 kcps. 5VDC/12 VDC/24 VDC.I/O Terminal Cover For 20-pin block, standard C500-COV13I/O Control UnitHigh-speed Counter Unit
A High-speed Counter Unit counts input signals from incremental rotary encoders or other sources.
Name: High-speed Counter Module CQM1H-ME16K System Manual.
Model: C200H-CT002.
Number of axes: 1 axis/Unit.
Operating modes: 6.Description : Connects peripheral port to D-sub 9pin connector.
Must be used with CS1W-CN114 (3.3m).Connects CQM1H to G730 SYSMAC BUS remote I/O
modules; max. 64 I/O (32 or 16 inputs or outputs, DIP switch selectable)
Number of I/O points per Master: 128
Communications cycle time: 187.5 kbps
Max. transmission distance: 200 m
One master and two expansions allowed per systemModel : C500-LK103-P.
APF/ PCF.Applicable CPU Units: CQM1H-CPU51/61.
Pulse inputs: 4 inputs.
External outputs: 4 outputS.
Current consumption (Supplied from Power Supply Unit): 5 V DC, 400 mA max.
Dimensions: 25 × 110 × 107 mm (W × H × D).
Weight: 90 g max.
Unit classification: CJ1 Special I/O Units.
Product name: Process Analog Input Units,
(Isolated-type Resistance Thermometer Input Units).
Input points: 4 inputs.
Signal range selection: Common inputs.
Signal range: Resistance thermometer: Pt100, JPt100.
Conversion speed (resolution): Conversion,
speed: 250 ms/4 inputs.
Accuracy at ambient temperature of 25°C:
Accuracy: (±0.3% of PV or ±0.8°C,
whichever is larger) ±1 digit max.
External connection: Removable terminal block.
No. of unit numbers allocated: 1.
Cuurrent consumption: 5V, 0 CQM1H-ME16K Manual. 25A; 24V, --.
Standards: UC1, CE.
A Single Unit Handling All Types of Inputs,
such as Temperature Sensor Inputs and,
Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5V).
A Unit supports four inputt channels,
each of which can be set to a
platinum resistance thermometer, thermocouple,
and DC signal (current, voltage) CQM1H-ME16K Manual.
All inputs are isolated.