Model: CPM2C-16ET1C. Units with transistor outputs only.
1 Fujitsu connector.
Outputs: 16 outputs.
Input type: 24 VDC.
Output type: sourcing transistor.Name: Three-tier Screw Terminal Block.
Specifications: Outputs; 16 outputs; PNP;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet CS1D-CPU65S OPERATION MANUAL.
Branching is easily made with CompoNet
CS1D-CPU65S
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error CS1D-CPU65S OPERATION MANUAL. Unit type: CJ1 CPU Bus Units.
Product Name: Position Control,
Unit with MECHATROLINK-II interface.
Specifications: Control commands,
executed by MECHATROLINK-II,
synchronous communications.
Direct operation by ladder programming.
Control mode: Position control,
speed control or torque control;
No CS1D-CPU65S OPERATION MANUAL. of axes: 16 axes.
No. of unit numbers allocated: 1.
Current consumption : 5V, 0.36A; 24V,--.
Standards: UC1, CE.
Decrease TCO with Simple Operation,
Reduced Wiring, Batch Settings,
and Batch Management.
Control Servos for up to 16 axes in,
a motion network with one Position,
Control Unit that supports MECHATROLINK-II.
MECHATROLINK-II is a registered trademark,
of the MECHATROLINK Members Association. Name: Space Module.
Model: C200H-BAT09.
Description: Replacement for memoryModel : C500-PS223-E.
100 to 120 VAC or 200 to 240 VAC (selectable).
Output ratings: 12 A, 5 VDC.C500-ID I/O Unit DC Input 16 pts C500-ID213(3G2A5-ID213).
DC12-24V 10mA.Unit type: CS1 Special I/O Units.
Product name: Power Transducer Input Unit.
Input points : 8 inputs.
Signal range: 0 to 1 mA, ±1 mA.
Conversion speed (resolution):
200ms/8 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.08A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and spacce compared,
with previous systems CS1D-CPU65S Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CS1D-CPU65S Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.