Model: C200HW-PA209R.
Supply voltage: 100 to 120 VAC, 200 to 240 VAC.
Comments: With output contacts during operation.Product name: N@@S1- type CPU Units with 40 I/O Points.
Specifications: Power Supply, 100 to 240 VAC; Inputs, 24; Outputs, 16;
Output type: Relay.
Program capacity: 8K steps.
memory Data capacity: 8K words CS1G-CPU44H HOST CONNECTION MANUAL.
External powersupply(24 VDC): 0.30A
CS1G-CPU44H
Current consumption: 5 V, 0.21A; 24 V,0.09A.
Standards: CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection CS1G-CPU44H HOST CONNECTION MANUAL. Unit type: CJ1 Basic I/O Units.
Product name: AC Input Units.
Specifications: I/O points, 8 inputs;
Input voltage and current: 200 to 24 VAC, 10 mA(200V, 50Hz);
Commons, 8 points, 1 common; External connection,
Removable Terminal Block; No. of words allocated, 1 word.
Current consumption: 5V, 0.08A; 24V, --.
Standards: UC1, N, L, CE CS1G-CPU44H HOST CONNECTION MANUAL.
A Wide Range of Basic Input,
Units for High Speed Input and,
Different Applications.
Receive ON/OFF signals from external,
devices into the PLC System to update,
I/O memory in the CPU Unit.
New high-speed input models CJ1W-ID212 and,
CJ1W-ID233 are now available. These units can,
help to increase system throughput.
Output method: Relay.
Inputs: ---.
Outputs: 16.Model: C200H-MD501.
No. of I/O pts: 16 inputs, 16 outputs.
Specifications: 5 VDC.I/O points: 256 pts.
Program capacity(words): 7.2 K.
DM capacity (words): 6 K.
RS-232C port: YES.
Analog setting: YES.Communi-cations cable: 100Base-TX.
CJ1W-ETN11 Ethernet Communications services: FINS communications, FTP server, socket services, and mail services.
Unit numbers: 0 to F (4 Units max.).Name: e-CON Connectors.
Specifications: Inputs; 32 inputs; NPN;
Without Short-circuit and,
Disconnected Line Detection.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-leveel I/O distribution reduces,
wiring in the system CS1G-CPU44H Communications Commands Manual.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on sitee CS1G-CPU44H Communications Commands Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error.