Power supply: DC power supply.
Output method: Transistor output sink type.
Inputs points: 18 points.
Outputs points: 12 points.Model: CPM2A-30CDT-D. Power supply: DC power supply.
Output type: Transistor sinking.
Inputs points: 18 points.
Outputs points: 12 points.Output method: Transistor sinking.
Inputs: --- CS1W-CLK13 (H-PCF CABLE) Installation Guide.
Outputs: 8.24 VDC, Wired.Model: CPM2C-32EDTC
CS1W-CLK13 (H-PCF CABLE) Units with 32 I/O points
2 Fujitsu connectors.
Inputs: 16 inputs.
Outputs: 16 outputs.
Input type: 24 VDC.
Output type: sinking transistor.Unit type: CJ1 CPU Bus Units.
Product Name: Position Control,
Units with EtherCAT interface.
Specifications: Control output interface,
Control commands executed by,
EtherCAT communications.
Positioning functions: Memory operation,
Direct operation by ladder programming,
I/O communications: 64 nodes;
No CS1W-CLK13 (H-PCF CABLE) Installation Guide. of axes: 4 axes.
No. of unit numbers allocated: 1.
Current consumption : 5V, 0.46A; 24V,--.
Standards: UC1, CE.
Preeminent control performance and,
easy operation feature of EtherCAT,
improve the production efficiency.
The EtherCAT communications with,
100Mbps baud rate enables fast,
and accurate position control CS1W-CLK13 (H-PCF CABLE) Installation Guide.
A wide range of position control,
functions are available with,
this position control unit. CVM1-CL Special I/O Unit Communication Link Unit CVM1-CLK21.Model : C500-MR831.Model: C200H-PS221.
Supply voltage: 120/240VAC.For Hand-held Programming Console.
2m.Output method: Transistor sourcing.
Inputs: 24.
Outputs: 16.Unit type: CS1 Special I/O Units.
Product name: Isolated-type DC Input Unit.
Input points : 4 inputs.
Signal range: 4 to 20 mA, 0 to 20 mA,
0 to 10 V, ±10 V, 0 to 5 V, ±5 V,
1 to 5 V, 0 to 1.25 V, ±1.25 V.
Conversion speed (resolution):
20 ms/4 inputs, 10 ms/2 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.12A.
Standards: UC1, N, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,
with previous systems CS1W-CLK13 (H-PCF CABLE) Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CS1W-CLK13 (H-PCF CABLE) Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.