Product name: CJ-series I/O Control Unit.
Specifications: One I/O Interface Unit is,
required on each Expansion Rack.
Connecting Cable: CS1W-CN@@3 Expansion,
Connecting Cable Mount to the right of,
the Power Supply Unit.
Current consumption: 5V , 0.02A;
24V, --.
Standards: UC1, N, L, CE.
Expand CJ/NJ-series with These Units CV500-BSC51 Macro Reference.
To expand a CJ/NJ-series Controller,
connect an I/O Control Unit to the CPU Rack,
and I/O Interface Unit to the Expansion Rack,
and connect the two Units with I/O Expansion Cable
CV500-BSC51 CPU Unit: CP1H-Y CPU Units.
Specifications: CPU type, Memory capacity: 20K steps,
High-speed counters: 1 MHz, 2 axes 100 kHz, 2 axes Pulse,
outputs: 1 MHz, 2 axes 100 kHz, 2 axes;
Power supply, DC power supply; Output method, Transistor output (sinking);
Inputs, 12+line-driver input, 2 axes; Output, 8+ine-driver output, 2 axes CV500-BSC51 Macro Reference.
Standards: UC1, N, L, CE.
4 Axis Position Control and Comprehensive Programmable Controller.
The CP1H-X with pulse outputs for 4 axes.
The CP1H-Y with 1-MHz pulse I/O.
The CP1H-XA with pulse outputs for 4 axes and built-in analog I/O CV500-BSC51 Macro Reference. Unit type: CJ1 Basic I/O Units.
Product name: Interrupt Input Unit.
Specifications: I/O points, 16 inputs;
Input voltage current, 24 VDC, 7mA;
Commons: 16 points, 1 common;
Input pulse widt conditions, ON time:
0.05 ms max. OFF time: 0.5 ms max;
Max. Units mountable per Unit, 2;
External connection, Removable terminal block.
No. of words allocated: 1 word.
Current consumption: 5V, 0.08A; 24V, --.
Standards: UC1, N, L, CE.
High-speed Starting of I/O InterruptTasks.
Use Up to Two Units for a Total of Up,
to 32 Interrupt Inputs.
Receive inputs to start I/O interrupt tasks.
When the Interrupt Input Unit receives an input,
the CPU Unit will interrupt execution of the,
cyclic tasks in the normal.
program and execute an I/O interrupt task. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Analog Output Unit.
Output points : 4 inputs.
Signal range selection:
Set separately for each input.
Signal range: 0 to 10 V, ±10 V,
0 to 5 V, ±5 V, 0 to 1 V, ±1 V.
Conversion speed (resolution):
40ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.12A; 26V, 0.12A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and spacce compared,
with previous systems CV500-BSC51 Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CV500-BSC51 Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.