Release Key Type: Standard (metal).
Wiring method: Terminal block.
Solenoid voltage/Indicator: 24VDC (Orange).
Lock and release type: Mechanical lock Solenoid release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 5-contact Model,
Insert the built-in switch (E, F, G or H) into the blank @ DRT1-DA02 OPERATION MANUAL.
Conduit size (See Note.): G1/2
DRT1-DA02
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available) DRT1-DA02 OPERATION MANUAL.
Key holding force of 1,300 N.
It is possible to change the key insertion point.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lock Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames.
The plastic material makes the Slide Key suitable,
for lightweight doors DRT1-DA02 OPERATION MANUAL. Actuator: Plunger.
Conduit size: 2-conduit; M20.
Built-in switch mechanism: 1NC/1NO MBB(Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Specifications: Input, PNP (- common), 8 points.
I/O connections: Sensor I/O connector.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: Supplied from the communications connector.
Environment-resistive (IP67) I/O.
Terminals with Troubleshooting.
Functions such as Sensor Power.
Supply Short-circuit Detection.
Equipped with the standard Smart Slave functions that provide powerful,
preventative maintenance and troubleshooting capabilitties DRT1-DA02 Manual.
High degree of environmental resistance with dust-proof,
and drip-proofconstruction.
Power supply wiring is not required for input devices.
Connect heavy-load devices (up to 1.5 A).
Power supply wiring is not required forr input devices such as sensors DRT1-DA02 Manual.
(Power supply wiring is required for output devices.)
Detects ground faults or disconnects and notifies the Master.