OMRON GRT1-TS2P Manual GRT1-TS2P REFERENCE MANUAL
Product model: GRT1-TS2P
Name: Analog I/O Units
Brand: OMRON
Sort: REFERENCE MANUAL
File language: English
Number of phases: Single-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: No.
Applicable load: 35 A, 100 to 240 VAC.
Compact, Slim-profile SSRs with Heat,
Sinks. Models with No Zero Cross for,
a Wide Range of Applications GRT1-TS2P REFERENCE MANUAL.
RoHS compliant.
Models also available with no zero cross,
Surge pass protection improved surge dielectric strength for,
output currents GRT1-TS2P (OMRON testing).
Compact with a slim profile.
Mount to DIN Track or with screws.
Conforms to UL, CSA, and EN standards (TÜV certification). Name: Safety Controller.
Number of I/O: Safety inputs, 20; Test outputs, 6;
Safety outputs, Solid-state outputs: 8; Standard outputs, -- GRT1-TS2P REFERENCE MANUAL.
Unit version: Ver.2.0.
Easy programming for complex safety control.
Stand-alone Safety Controller for small and mid-sized machinery.
Three types of CPU with different I/O size to suit the application.
Four types of Expansion I/O Units for hard-wired diagnosis or standard signals.
Clear diagnosis and monitoring via Ethernet or Serial connection.
Various kinds of safety devices directly connectable like noncontact,
switches and safety mats GRT1-TS2P REFERENCE MANUAL.
Easy design, verification, standardization and reusage of,
safety control by unique programming software.
ISO 13849-1 (PLe/Category 4), IEC61508 (SIL3) certified. Type: output module.
Insulation: photo coupler.
Zero crossing function: No.
Action display lamp.
Output rated voltage: AC100 3A ~ 240V.
Input rated voltage: DC5 ~ 24V.
Logic circuit and load interface.
I/O solid state relay.
With the input module (AC, DC), the output module (AC, DC).
Product series, the color of each module to distinguish.
You can confirm the action of SSR by using the action display light.
Between input and output voltage 4000V. Easy-to-use, Simple Magnetic.
Proximity Sensor.
Permanent magnetic used to operate the reed switch.
Ideal for detecting opening and closing of doors. Contact configuration: Four SPST-NO relays.
Heat sink: No.
Built-in SSRs: G3S-201PL-PD.
Zero cross function: No.
Applicable output load: 0.66 A at 75 to 264 VAC(See note 1 GRT1-TS2P Manual. ).
Rated voltage: 5 VDC, 12 VDC, 24 VDC.
Compact Terminal SSR with 4 Outputs.
Easy-to-use SSR block that combines four compact G3S SSRs,
sockets, and heat sink in one unit.
Easy wiring with sepaarate I/O terminal construction GRT1-TS2P Manual.
LED operation indicator.
Special socket used for easy Relay replacement.
Mounts either on DIN track or with screws.
Related products
OMRON
CompoNet Communications Unit
GRT1-IA4-2
OMRON CompoNet Communications Unit GRT1-IA4-2
Name: Slice I/O Units Digital I/O Units
OMRON
CompoNet Communications Unit
GRT1-CT1-1
OMRON CompoNet Communications Unit GRT1-CT1-1
Name: Slice I/O Units Counter Units.
OMRON
CompoNet Communications Unit
GRT1-IA4-1
OMRON CompoNet Communications Unit GRT1-IA4-1
Name: Slice I/O Units Digital I/O Units
OMRON
CompoNet Communications Unit
GRT1-OD4
OMRON CompoNet Communications Unit GRT1-OD4
Name: Slice I/O Units Digital I/O Units