Product model: H5S-WFA2D
Name: Digital Controllers
Brand: OMRON
Sort: User's Manual
File language: English
Supply voltage: 24 VDC.
Time-limit contact: 4PDT(Twin contacts).
Long-time range model(0.1 min to 10 h).
Miniature Timer with Multiple Time.
Ranges and Multiple Operating Modes.
Minimizes stock.
Pin configuration compatible with MY Power Relay.
Standard multiple operating modes and multiple time ranges H5S-WFA2D User's Manual.
Conforms to EN 61812-1 and IEC 60664-1 for Low Voltage,
and EMC Directives H5S-WFA2D Type: H5CX-B series.
Time specifications: 0.01 to 9999.99 s, 1 s to 99 h 59 min 59 s,
0.1 to 99999.9 min, 0.1 to 99999.9 h.
Operating modes: A: Signal ON Delay I, F-1: Cumulative.
External connections: Screw terminals.
Input: Signal, Reset, Gate (NPN/PNP input).
Output: Transistor output (DPST).
Supply voltage: 12 to 24 VDC H5S-WFA2D User's Manual.
The Timer with the Shortest Body,
in the Industry. Outputs: Time-limit contact and instantaneous contact .
Supply voltage: 110 VAC (50/60 Hz); 220 VAC (50/60 Hz).
A wide star-time range (up to 120 seconds) and star-delta,
transfer time range (up to 1.0 seconds).
Setting rings (order separately) to enable consistent settings,
and to limit the setting range.
Panel Covers (order separately) to enable various panel designs H5S-WFA2D User's Manual.
Approved by UL, CSA, CE and CCC. Count input: PNP/NPN universal DC voltage input (4.5 to 30 VDC).
Display: 7-segment LCD.
Max. revolutions displayed (applicable encoder resolution):
1000.0 s–1 (10 pulse/rev.), 1000.0 min–1 (600 pulse/rev.),
←→10000 min–1 (60 pulse/rev.) (switchable). ; Black body.
Revolutions displayed up to five digits.
Dual revolution display according to encoder resolution used;
1000 s–1/1000 min–1 or 1000.0 s–1 /1000.0 min–1,
Switchable dual revolution display type available (-NV1 models);
extended up to 10000 min–1. Type: H5CX-A series.
Time specifications: 0.001 to 9.999 s, 0.01 to 99.99 s,
0.1 to 999.9 s, 1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min,
1 to 9999 min, 1 min to 99 h 59 min, 0.1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode, A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,
Z: ON/OFFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2 H5S-WFA2D Manual.
External connections: Screw terminals.
Input: Signal, Reset, Gate (NPN/PNP input) H5S-WFA2D Manual.
Output: Contact output (time-limit SPDT).
Supply voltage: 100 to 240 VAC.
The Timer with the Shortest Body,
in the Industry.
Related products
OMRON
Digital Time Switch
H5S-WFB2
OMRON Digital Time Switch H5S-WFB2
Control cycle: Weekly. Numer of output
OMRON
Digital Time Switch
H5S-WB2
OMRON Digital Time Switch H5S-WB2
Control cycle: Weekly. Numer of output
OMRON
Digital Time Switch
H5S-YB4-X
OMRON Digital Time Switch H5S-YB4-X
Control cycle: Yearly. Numer of output
OMRON
Digital Time Switch
H5S-YFB4-X
OMRON Digital Time Switch H5S-YFB4-X
Control cycle: Yearly. Numer of output