OMRON H5S-WFB2 Manual H5S-WFB2 User's Manual
Product model: H5S-WFB2
Name: Digital Controllers
Brand: OMRON
Sort: User's Manual
File language: English
Count input: PNP/NPN universal DC voltage input(4.5 to 30 VDC).
Max. counting speed: 30 Hz ←→ 1 kHz(switchable).
Display: 7-segment LCD.
Model: Light-gray body.
Eight-digits, counting range 0 to 99999999.
Dual input speed: 30 Hz ←→ 1 kHz,
(except for AC/DC multivoltage input models). Type: H5CZ H5S-WFB2 User's Manual.
Time specifications: 0.001 to 9.999 s, 0.01 to 99.99 s, 0.1 to 999.9 s,
1 to 9999 s, 1 s to 99 min 59 s, 0 H5S-WFB21 to 999.9 min, 1 to 9999 min,
1 min to 99 h 59 min, 0.1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,
Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2 H5S-WFB2 User's Manual.
External connections: 8-pin socket.
Inputs: Signal, Reset (NPN inputs).
Outputs: Contact output (time-limit SPDT).
Supply voltage: 100 to 240 VAC.
Easy to Use and Easy to Read.
Basic Features.
Character height of 10 mm for better readability H5S-WFB2 User's Manual.
Operation is simplified by the Up/Down Keys for each digit on 4-digit.
Safety and Reliability.
Power supply circuit and input circuits are isolated for safety and reliability.
Set value limit function prevents unexpected operation of output devices.
caused by setting mistakes.
Output counter function helps in managing the service life of the Timer or,
the load.
Other Features.
Models with instantaneous contact output.
Waterproof, dust-proof structure (UL508 Type 4X and IP66).
Key protection. Type: H5CZ.
Time specifications: 0.001 to 9.999 s, 0.01 to 99.99 s, 0.1 to 999.9 s,
1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min, 1 to 9999 min,
1 min to 99 h 59 min, 0.1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,
Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2.
External connections: 8-pin socket.
Inputs: Signal, Reset (NPN inputs).
Outputs: Contact output (time-limit SPDT).
Supply voltage: 12 to 24 VDC/24 VAC.
Easy to Use and Easy to Read.
Basic Features.
Character height of 10 mm for better readability.
Operation is simplified by the Up/Down Keys for each digit on 4-digit.
Safety and Reliability.
Power supply circuit and inpput circuits are isolated for safety and reliability H5S-WFB2 Manual.
Set value limit function prevents unexpected operation of output devices.
caused by setting mistakes.
Output counter function helps in managing the service life of the Timer oor,
the load H5S-WFB2 Manual.
Other Features.
Models with instantaneous contact output.
Waterproof, dust-proof structure (UL508 Type 4X and IP66).
Key protection.
Related products
OMRON
Digital Time Switch
H5S-YB4-X
OMRON Digital Time Switch H5S-YB4-X
Control cycle: Yearly. Numer of output
OMRON
Digital timing switch
H5S-YFA2-X
OMRON Digital timing switch H5S-YFA2-X
Control cycle: one year. Output numer:
OMRON
Digital Time Switch
H5S-YB2-X
OMRON Digital Time Switch H5S-YB2-X
Control cycle: Yearly. Numer of output
OMRON
Digital timing switch
H5S-WA2
OMRON Digital timing switch H5S-WA2
Control cycle: a week. Output numer: 2