OMRON H7EC-NP Manual H7EC-NP Communications Manual
Product model: H7EC-NP
Name: Digital Controllers
Brand: OMRON
Sort: Communications Manual
File language: English
Output: Contact.
Supply voltage: 100 to 240 VAC (50/60 Hz)/100 to 125 VDC;
24 to 48 VAC (50/60 Hz)/12 to 48 VDC.
Input type: Voltage input.
Time range: 0.05 s to 300 h.
Operating mode (See note 2): Eight multi-modes: A, B, B2, C, D, E, G, J.
Multiple Operating Modes and Multiple Time.
Ranges. DIN 48 x 48-mm Multifunctional Timer H7EC-NP Communications Manual.
A wide AC/DC power supply range greatly reduces the number,
of timer models kept in stock H7EC-NP
A wide range of applications with multiple operating modes,
eight modes for 11-pin models and five modes for 8-pin models.
Ecological design with reduced current consumption.
Easy sequence checking with instantaneous outputs for a zero set value.
Length of 75 mm or less when panel-mounted with a P3G-08,
Socket (H3CR-A8E, 100 to 240 VAC, 100 to 125 VDC),
PNP input models available H7EC-NP Communications Manual.
Standards: UL, CSA, NK, LR, CCC, EN 61812-1, and CE Marking. Type: H5CX-L series.
Time specifications: 0.001 to 9.999 s, 0.01 to 99.99 s,
0.1 to 999.9 s, 1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min,
1 to 9999 min, 1 min to 99 h 59 min, 0.1 to 999.9 h, 1 to 9999 h H7EC-NP Communications Manual.
Operating modes: Timer Mode, A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,
Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2.
External connections: 8-pin socket.
Input: Signal, Reset (NPN input).
Output: Transistor output(SPST).
Supply voltage: 12 to 24 VDC/24 VAC.
The Timer with the Shortest Body,
in the Industry. Outputs: Time-limit contact annd instantaneous contact H7EC-NP Manual.
Supply voltage: 110 VAC (50/60 Hz); 220 VAC (50/60 Hz).
A wide star-time range (up to 120 seconds) and star-delta,
transfer time range (up to 1.0 seconds).
Setting rings (order separately) to enable connsistent settings,
and to limit the setting range H7EC-NP Manual.
Panel Covers (order separately) to enable various panel designs.
Approved by UL, CSA, CE and CCC.
Related products
OMRON
PCB-mounting Counters
H7EC-NLP
OMRON PCB-mounting Counters H7EC-NLP
Count input: No-voltage input. Display:
OMRON
Self-powered Tachometer
H7ER-NV-BH
OMRON Self-powered Tachometer H7ER-NV-BH
Count input: PNP/NPN universal DC voltag
OMRON
Self-powered Time Counter
H7ET-N
OMRON Self-powered Time Counter H7ET-N
Timer input: No-voltage input. Display:
OMRON
Self-powered Time Counter
H7ET-NFV-B
OMRON Self-powered Time Counter H7ET-NFV-B
Timer input: AC/DC multi-voltage input 2