LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
OMRON H7EC-NV Manual H7EC-NV Communications Manual
Product model: H7EC-NV
Name: Digital Controllers
Brand: OMRON
Sort: Communications Manual
File language: English
Operating method: Reversible (selectable with rotary DIP switch) between,
0 and the set value; Incrementing/decrementing A/D (command inputs);
Incrementing/decrementing B/E (individual inputs);
Incrementing/decrementing C/F (phase difference inputs).
Mounting method: Flush mounting.
Operation modes: N, F, C, R, K, P, Q (selectable with rotary DIP switch) H7EC-NV Communications Manual.
Input signal method (Count and reset inputs): Contact and transistor input, voltage (H and L) H7EC-NV
Control output: 1-stage counters: Contact (SPDT) and transistor,
output (H and L output switchable);
2-stage counters: Contact (SPST-NO) and transistor output,
(H and L output switchable).
Set value read: Continuous mode.
Memory backup: No H7EC-NV Communications Manual.
Display: Yes (10-mm high 7-segment LED, Up indicator).
Models: 2 digits; 1 stage.
A DIN 72 x 72 mm Best-selling Counter.
Easy setting with thumbwheel switches.
A draw-out construction enables maintenance without rewiring.
Models with 2-, 4-, 6-, or 8-digit displays are also available.
Total Counter models are also Available.
Complies with UL and CSA Marking. Type: H5CX-A series H7EC-NV Communications Manual.
Time specifications: 0.001 to 9.999 s, 0.01 to 99.99 s,
0.1 to 999.9 s, 1 to 9999 s, 1 s to 99 min 59 s, 0.1 to 999.9 min,
1 to 9999 min, 1 min to 99 h 59 min, 0.1 to 999.9 h, 1 to 9999 h.
Operating modes: Timer Mode, A: Signal ON Delay I, A-1: Signal ON Delay II,
A-2: Power ON Delay I, A-3: Power ON Delay II, b: Repeat cycle 1,
b-1: Repeat cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulative,
Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, Twin Timer Mode,
toff: Flicker OFF Start 1, ton: Flicker ON Start 1,
toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2.
External connections: Screw terminals.
Input: Signal, Reset, Gate (NPN/PNP input).
Output: Transistor output(SPST).
Supply voltage: 100 to 240 VAC.
The Timer with the Shortest Body,
in the Industry. Supply voltage: 12 VDC.
Control output: Contact output, DPDT (time-limit DPDT,
or time-limit SPDT + instantaneous SPPDT) Changed using a switch H7EC-NV Manual.
Eight-mode Timer.
Multiple time ranges and operating modes let you cover a wide,
range of applications.
The time-limit DPDT output contacts can be changed to time-limit,
SPDT and instantaneous SPDT ooutput contacts using a switch H7EC-NV Manual.
Sequence checks are easily performed by setting an instanta,
neous output to 0.
Start signal control for the H3DK-M.
Related products
OMRON
Self-powered Tachometer
H7ER-N
OMRON Self-powered Tachometer H7ER-N
Count input: No-voltage input. Display:
OMRON
Self-powered Time Counter
H7ET-NFV
OMRON Self-powered Time Counter H7ET-NFV
Timer input: AC/DC multi-voltage input 2
OMRON
Self-powered Time Counter
H7ET-NV-H
OMRON Self-powered Time Counter H7ET-NV-H
Timer input: PNP/NPN universal DC voltag
OMRON
Self-powered Tachometer
H7ER-NV1-H
OMRON Self-powered Tachometer H7ER-NV1-H
Count input: PNP/NPN universal DC voltag