LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
OMRON K2CM-4M Manual K2CM-4M Communications Manual
Product model: K2CM-4M
Name: Digital Temperature Controllers
Brand: OMRON
Sort: Communications Manual
File language: English
Input type: NPN/ voltage pulse input type.
Event input terminal 5 points (HOLD, RESET) equipped with.
External power supply DC12V80mA.
Note: K3HB-RPB-A, K3HB-RNB-A is not equipped with event input.
Relay contact: H; PASS1c, L, each 1c.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V K2CM-4M Communications Manual.
Measurement of 2 points through the speed, time, or cycle of the digital time interval table K2CM-4M
Action determine the color, can switch the green / Red 2 kinds of color display.
Measurement of wide range of pulse interval time.
Measuring, calculating and displaying the pulse interval between 2 points.
Pulse interval measurement range, the maximum can be measured from 10ms to 3200sTime specification: Inverse type K2CM-4M Communications Manual.
Current setting range: 20 to 65 A.
Operating voltage: 400/440 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button K2CM-4M Communications Manual.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Type of input: AC current input.
Output type: no output.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) some models are not equipped with depth.
The most suitable voltage and current signal simulation, measuremeent and display, identification of the panel table K2CM-4M Manual.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input cann be applied to a variety of measurement and identification situations K2CM-4M Manual.
Series of DeviceNet type.
The depth (panel below) is only short size 95mm.
UL
Related products
OMRON
Heater Element Burnout Detector
K2CU-P2-B
OMRON Heater Element Burnout Detector K2CU-P2-B
Control supply voltage: 110/220 VAC Wit
OMRON
Heater Element Burnout Detector
K2CU-P1A-A
OMRON Heater Element Burnout Detector K2CU-P1A-A
Control supply voltage: 100/ 200 VAC Wi
OMRON
Motor Protective Relay
K2CM-Q2LS
OMRON Motor Protective Relay K2CM-Q2LS
Time specification: Instantaneous type.
OMRON
Motor Protective Relay
K2CM-Q4HA
OMRON Motor Protective Relay K2CM-Q4HA
Time specification: Instantaneous type.