Time specification: Instantaneous type.
Current setting range: 50 to 160 A.
Operating voltage: 400/440 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
rent, open-phase, and reverse-phase.
ing the test button.
is indicated from the start of operation.
Space-saving, integrated construction.
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.
Power supply voltage: 24V DC±10%, Ripple (p-p): 10%.
Current consumption: 0.9A max.
Discharge voltage: ±7.5kV.
Discharge method: Variable DC.
Ionization time: 1.5 s.
Ion balance: ±10V max.
Amount of ozone generated: 0.01 ppm,
(Measured at a distance of 50 mm from air outlet).
Indicators: Power (Green), Fan running (Green), Cleaning (Yellow), Alarm (Red) OMRON K2CM-Q4HA.
Main functions: Ion balance adjustment (Automatic and manual)
K2CM-Q4HA
External output (for both cleaning and alarm outputs): Photo MOS relay output,
(NPN or PNP)Applied voltage: 30VDC max., load current: 100mA max.
Residual voltage: 1V max.
Discharge stop input: No-voltage contact input, ON: 0V short circuit,
OFF: Open (leakage current: 0 OMRON K2CM-Q4HA. 1mA max.).
Ambient temperature range: 0 to 50˚C (No icing or dewing).
Ambient humidity range: 35% to 65% (No icing or dewing).
Weight (Packaged): Approx. 0.6 kg (Approx. 1.2 kg).
Material: Body:Aluminum, ABS Electrode needle: Tungsten.
Accessories: Instruction sheet, I/O connector, L-mounting bracket, Streamer.
This ionizer series is designed to go anywhere.
All models are easily installed on narrow,
workbenches or in high positions where earlier,
models presented installation issues OMRON K2CM-Q4HA. Cable length L: A, 5.0 m; B, 4.75 m.
Connect Connector-Terminal,
Block Conversion Units (XW2@) to,
I/O Units for Programmable,
Controllers with one touch. Protect motors and other equipment from unstable,
voltages in the power supply system.
Protect motors and other equipment by detecting,
overvoltages, undervoltages, phase sequence, and,
phase loss for three-phase power supplies.
Phase loss detection while the motor is operating.
Global power supply support. (Changed with a switch.).
Greater resistance to inverter noise.
Wiidth of 17 K2CM-Q4HA. 5 mm to reduce space required in panels.
Push-In Plus Terminal that reduce wiring work.
The use of cage clamps enables wiring with bare stranded wires.
Double-insertion holes for crossover wiring (all terminals).
UL listed ffor easy shipping to North America K2CM-Q4HA.
Certification is pending for LR standards.
Models added with transistor outputs for superior contact reliability.