OMRON K2CM-Q4LA Manual K2CM-Q4LA Communications Manual
Product model: K2CM-Q4LA
Name: Digital Temperature Controllers
Brand: OMRON
Sort: Communications Manual
File language: English
Models: OCR-H (51).
Protection of distributed power supply connection to power system,
The relay is smaller, and the protection unit is more enriched.
Waste heat generation system improve the comprehensive energy efficiency and the use of natural,
Energy of wind power generation, the spread of power is becoming more and more popular K2CM-Q4LA Communications Manual.
This relay is used to detect the internal fault of the user in the distributed power supply,
Power line accident of distributed power supply and relay protection system K2CM-Q4LA
The relay can be meet in Japan (system connected instant points specified in the standard model),
Function, can be through more than 20 kinds of products to establish the best protection system K2CM-Q4LA Communications Manual.
Can also correspond to the generator and the electric side / internal tributaries.
Unit with 2 relay elements.
In each unit, the variable action time circuit is hidden, so that the coordination design is more convenient.
All aircraft equipped with a locking relay terminal.
DSR can correctly determine the direction of the sudden drop in the voltage to 0 of the short-circuit accident.
2 stage cross terminal stand with cover with convenient wiring K2CM-Q4LA Communications Manual. Rated primary current: 50 A.
Rated secondary current: Special output.
Installation: Installed separately.
High-performance Power Monitor Suitable for On-panel Mounting and Display.
Assists Energy-saving Analysis.
Energy classification for wasted standby and stopped power.
(Classification based on external inputs is also supported.)
Power and current can be measured simultaneously.
Measurement of flow rates with a pulse conversion function.
Simple temperature measurements with Temperature Sensor included in the Unit.
High-precision Measurements.
Measurement of generated power (regenerative power),
leading reactive power, lagging reactive power, and consumed power.
Power measurements on the primary side of inverters,
which are widely used to save energy.
Automatic range switching for accurate measurement of standby and stopped power.
Energy-saving Functions.
Conversion to monetary cost. (Also used for classified standby and stopped powerr K2CM-Q4LA Manual. )
Alarm outputs can be selected for active power, reactive power,
regenerative power, current, voltage, or power factor.
The Power Monitor can log measurement data and supports Modbus communications.
Installation and Settingss K2CM-Q4LA Manual.
Direct measurement of three-phase, four-wire, 400-V line voltage.
Simple measurements without voltage wiring.
Incorrect voltage wiring detection.
Related products
OMRON
Motor Protective Relay
K2CM-4H
OMRON Motor Protective Relay K2CM-4H
Time specification: Inverse type. Curren
OMRON
Motor Protective Relay
K2CM-Q1L
OMRON Motor Protective Relay K2CM-Q1L
Time specification: Instantaneous type.
OMRON
Motor Protective Relay
K2CM-1H
OMRON Motor Protective Relay K2CM-1H
Time specification: Inverse type. Curren
OMRON
Motor Protective Relay
K2CM-1MA
OMRON Motor Protective Relay K2CM-1MA
Time specification: Inverse type. Curren