OMRON K3HB-VLC-B-DRT1 Manual K3HB-VLC-B-DRT1 User's Manual
Product model: K3HB-VLC-B-DRT1
Name: Digital Temperature Controllers
Brand: OMRON
Sort: User's Manual
File language: English
Type of input: AC current input.
Output type: communication; RS-485; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with K3HB-VLC-B-DRT1 User's Manual.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table K3HB-VLC-B-DRT1
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DeviceNPower supply voltage: 100 to 240 VAC K3HB-VLC-B-DRT1 User's Manual.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: Two transistor outputs.
Communications output: RS-485.
Current input range: 0.200 to 2.200 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods K3HB-VLC-B-DRT1 User's Manual.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). Three-phase Phase-sequence Phase-loss.
Relay Using Voltage Detection Methhod K3HB-VLC-B-DRT1 Manual.
Fixed phase Asymmetry monitoring.
Prevents reverse motor rotation due to incorrect wiring.
Distinguishes between positive phases, reversed phases, and phase,
loss when power is turned ON.
Voltage detection method eenables application for any load current K3HB-VLC-B-DRT1 Manual.
One SPDT output relay, 6 A at 250 VAC (resistive load).
Output status can be monitored using LED indicator.