Control supply voltage: 100 VAC; With voltage fluctuation compensation.
Operating current: 16 to 40 A.
Accurate Detection of Heater Element.
Burnout Regardless of Heater Capacities.
Accurately detects a burned heater element or elements incor,
porated by a molding machine or packing machine and outputs,
an alarm signal K8AB-TH12S User's Manual.
Precisely singles out the burned element even if one heater el,
ement among several heater elements has been burned out
K8AB-TH12S
Applicable to small- to large-capacity heater elements.
All K2CU-F large-capacity, built-in current transformer models,
work with both single-phase and three-phase heaters.
Voltage fluctuation compensation function eliminates false,
alarms due to variations in the supply voltage K8AB-TH12S User's Manual. Time specification: Instantaneous type.
Current setting range: 20 to 65 A.
Operating voltage: 400/440 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase K8AB-TH12S User's Manual.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Time specification: Instantaneous type.
Current setting range: 2 to 8 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Automatic (See note.).
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicateed from the start of operation K8AB-TH12S Manual.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions K8AB-TH12S Manual. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM.