Function: Phase sequence and phase loss monitoring.
Rated input voltage: 3-phase, 3-wire 200 to 480 VAC.
Relay output: SPDT × 1.
Three-phase Phase-sequence Phase-loss.
Relay Using Voltage Detection Method.
Lineup includes a 17.5-mm slim, compact model.
Greater resistance to inverter noise.
Distinguishes between correct phases, phase sequence, and phase,
loss when power is turned ON K8AB-VS1 User's Manual
K8AB-VS1
Supports phase loss detection when the motor is operating.
Output status can be monitored using LED indicator.
Ideal to prevent reverse operation of motors. Type of input: AC current input.
Output type: transistor; -; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with K8AB-VS1 User's Manual.
External supply 80mA DC12V.
Power supply voltage: AC/DC24V.
96 (W) * 48 (H * 95mm) some models are not equipped with depth.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend K8AB-VS1 User's Manual.
External event input can be applied to a variety of measurement and identification situations.
DeviceNet type systemRated input: 3-phase 3-wire mode, 3-phase 4-wire mode;
200, 220, 230, 240 VAC, 115, 127, 133, 138 VAC.
Ideal for 3-phase Voltage Asymmetry.
Monitoring for Industrial Facilities and Equipment.
Greater resistance to inverter noise.
Monitor voltage asymmetry, phase sequence, and phase,
loss for three-phase 3-wire or 4-wire power supplies with just one Unit.
Switch setting for 3-phase 3-wire or 3-phase 4-wire power supply.
One SPDT output relay, 5 A at 250 VAC (resistive load).
World-wide power specifications supported by one Unit (switchable).
Relay status can be monitored using LED indicator. Category: external supply 100mA DC5V type.
Input type: load sensor, mV input type.
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
DeviceNet; DeviceNet:--.
96 (W) * 48 (H * 95mm) depth.
Power supply voltage: AC/DC24V.
To support the sensor input, the pressurre, load, torque and weight were measured,
Is an ideal indicator for judging whether an automatic device and a screening device are qualified K8AB-VS1 Manual.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equippped with the sub pressure gauge for monitoring the operation trend K8AB-VS1 Manual.
External event input can be applied to a variety of measurement and identification