LK Automation Limited LK Automation Limited
Download Sort: OMRON
Home >> Manual Download
OMRON SRT2-OD16-1 Manual SRT2-OD16-1 SETUP MANUAL
Product model: SRT2-OD16-1
Name: PROXIMITY SWITCH
Brand: OMRON
Sort: SETUP MANUAL
File language: English
Configuration: Covered Power Supplies.
Input voltage: 100 to 240 VAC (free) (80 to 370 VDC *).
S8JX-G15005@@:Switchable between 100 to 120 VAC and 200 to 240 VAC.
(DC power cannot be input.).
Power ratings: 35 W.
Output voltage: 24 V.
Output current: 1.5 A.
Built-in fan: No.
Easy-to-use, Widely range from 15 W to 600 W (Output Voltage: 5 V to 48 V) SRT2-OD16-1 SETUP MANUAL.
Easy Mounting: Front-mounted type, DIN rail-mounted type are available SRT2-OD16-1
Screw-mount at the top. (except 300-/600-W models).
Safety standards: UL 508/60950-1, cUL CSA C22.2 No. 107.1,
cUR CSA C22.2 No. 60950-1.
EN 50178 (= VDE 0160) Over voltage.
category III.
EN 60950-1 (= VDE 0805 Teil 1).
EMC: Conforms to EN 61204-3.
(EMI:EN55011 ClassA) SRT2-OD16-1 SETUP MANUAL.
Input conditions: The input voltage range of 15-W, 35-W,
50-W, 100-W, and 150-W models has,
been increased to 80 to 370 VDC (EC Directives and safety standards do not apply.).Input voltage: 24 VDC.
Output voltage: 24 VDC.
Output current/capacity: 20 A/480 W.
Compact DC-DC UPS with a DIN rail for,
mounting, best suited for prevention of,
voltage drop and power failure in,
industrial-purpose computers SRT2-OD16-1 SETUP MANUAL.
(IPC)/controllers.
System reliability greatly improved because.
24VDC power supply is backed up for a certain.
period of time in the event of voltage drop or power failure.
Compactness, weight reduction, and long battery life,
realized thanks to the adoption of a lithium-ion battery.
Push-in terminal block adopted for the power input and,
output I/F.
Shutdown in conjunction with the industrial,
purpose computer (IPC) or controller realized,
by the USB/RS-232C/I/O port installed in the UPS. Control power supply voltage: 100/110 VAC.
Input: DC, Input voltage range, 4 to 240 mV.
Overvoltage/Undervoltage Monitoring.
Relay for AC and DC Input.
Detect overvoltages or undervoltages (switch select,
able) from 4 mV to 300 V.
Detect undercurrent, reverse current, or overcurrent in,
DC circuits using shunt (SDV-FL).
Detect three-phase AC current for under and/or overcur,
rent using current converter.
Availlable in 7 supply voltage configurations SRT2-OD16-1 Manual.
Single-function model with ON-delay, OFF-delay, or star,
tup lock settings (SDV-FH@T).
Select either AC or DC voltage input.
Polarity can be specified (SDV-FL) to enable easy re,
verrse current detection SRT2-OD16-1 Manual.
Selectable reset value range from 2% to 30% of operat,
ing value (SDV-F).
LED operation indicator.
UL/CSA approval (SDV-F@).
Related products
OMRON
Remote I/O Modules
SRT2-ID16P
OMRON Remote I/O Modules SRT2-ID16P
I/O classification: Input. Internal I/O
OMRON
Transistor Remote I/O Terminals
SRT2-OD16-1
OMRON Transistor Remote I/O Terminals SRT2-OD16-1
I/O classification: Output. Internal I/