C200HG-CPU63-ZE OMRON CPU Unit C200HG-CPU63-ZE

Model : C500-PS211.
24 VDC.
Output ratings: 7 A, 5 VDC.
UM: 15.2K words.
DM: 6K words.
EM: 6K words.
Instruction processing time (basic instructions): 0.15 micro.s min.
No. of I/O points: 1, 184 points.
Max. no.of con-necting Expansion I/O Racks: 3 Racks.
Max C200HG-CPU63-ZE. no. of connecting High-density I/O Units(i.e., Group-2): Unavailable.
Max.. no. of con-necting Special I/O Units: 10.
RS-232C: NO.I/O Bus Connector Cover 3G2A5-COV01C500-OD I/O Unit Transistor Output 32 pts C500-OD412(3G2A5-OD412) C200HG-CPU63-ZE.
DC12~48V 0.3A.Unit classification: CJ1 Special I/O Units.
Product name: Temperature Control Units.
Specifications; No. of loops: 2 loops,
heater burnout detection function;
Temperature sensor inputs: Platinum ,
resistance thermometer input(JPt100, Pt100);
Control outputs: Open collector,
PNP outputs (pulses) C200HG-CPU63-ZE.
No. of unit numbers allocated: 2.
Current consumption: 5V, 0.25A; 24V, --.
Standards: UC1, N, L, CE.
A Single Unit Performing All the Functions of,
4 Temperature Controllers OMRON C200HG-CPU63-ZE.
A Special I/O Unit with direct input,
of thermocouple or resistance thermometer,
PID control with 2 degrees of freedom,
and open collector output. CV500-CN Cable Motion Control Connecting Cables 6 m CV500-CN624Unit type: CJ1 Special I/O Units.
Product name: Analog Output Unit OMRON C200HG-CPU63-ZE.
I/O points: 4 outputs;
Signal range selection:
Set separately for each output.
Signal range, Resolution: 1 to 5V(1/10,000),
0 to 10V(1/20,000), and -10 to 10V(1/40,000).
Conversion period: 20 μs/ 1 point,
25 μs/ 2 points, 30 μs/ 3 points,
35 μs/ 4 points The Direct conver sion is provided OMRON C200HG-CPU63-ZE.
Accuracy at ambient temperature of 25°C:
±0.3% of F.S.
External connection: Removable terminal block.
External power supply: --.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.40A; 24V, --.
Standards: UC1, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Analog Input Units for converting analog input,
signals into binary data.
Analog Output Units for converting binary ,
data into analog output signals. Power supply: AC power supply.
Output method: Relay output.
Inputs points: 6 points.
Outputs points: 4 points.ASCII Unit
This program runs indeependently from the ladder-diagram program in the PLC C200HG-CPU63-ZE.

Name: ASCII Module.
Model: C200H-ASC11.
Communications port>Port 1: RS-232C(peripheral device or termi-nal connection).
Communications port>Port 2: RS-232C(peripheral devi