LK Automation Limited LK Automation Limited
Brand Sort: OMRON
Home >> Price
S82H-3515 AC100/200 15V 3.4A Pirce
No PHOTO
OMRON S82H-3515 AC100/200 15V 3.4A
Release key type: Trapped key *1.
Indicator: Orange.
Lock and release types: Mechanical lock Solenoid release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 2NC/1NO+3NC.
Conduit opening: G1/2.
Holding Force of 3,000 N.
Two safety circuits and two monitor contacts provide an,
array of monitoring patterns.
Standard gold-clad contacts enable use with ordinary loads,
and microloads S82H-3515 AC100/200 15V 3.4A
Models with trapped keys prevent workers from being locked,
in hazardous work areas.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas.
IP67 degree of protection. C500-AD/3G2A5-AD Special I/O Unit Analog Input C500-AD006(3G2A5-AD006).
Input: 4 pts.
Specification: +1~+5V、4~20mA.Size: M8, Non-shielded.
Sensing distance: 4.0 mm.
Connection: M12 connector.
Body material: Stainless steel.
Thread length (overall length): 49 (65).
Output configuration: PNP.
Operation mode NO.
Safe Mounting with Greater.
Sensing Distance.
Ensures a sensing distance approximately 1.5 to 2,
times larger than that of any conventional OMRON Sensor.
Problems such as the collision of workpieces are eliminated.
Full range of standard sizes (M8, M12, M18 and,
M30; both long and short barrels).
Modular construction simplifies customization. Name: MIL Connectors.
Specifications: Outputs; 16 outputs ; PNP; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: ES1B power supply.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
S82H-3515 AC100/200 15V 3.4A Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=S82H-3515 AC100/200 15V 3.4A&select=5


...more relevant model market price >>>>
Related products