Operating method: Incrementing, decrementing, and reversible,
(UP/DOWN A to F) (selectable with rotary DIP switch).
Mounting method: Flush mounting.
Operation modes: N, F, C, R, K, P, Q (selectable with rotary DIP switch).
Input signal method (Count and reset inputs): Contact and transistor input, voltage (H and L).
Control output: 1-stage counters: Contact (SPDT) and transistor,
output (H and L output switchable);
2-stage counters: Contact (SPST-NO) and transistor output,
(H and L output switchable)
S8EX-N03015
Set value read: Continuous mode, Reset mode (selectable).
Memory backup: No .
Display: Yes (8-mm high 7-segment LED, Up indicator).
Models: 6 digits; 2 stage.
A DIN 72 x 72 mm Best-selling Counter.
Easy setting with thumbwheel switches.
A draw-out construction enables maintenance without rewiring.
Models with 2-, 4-, 6-, or 8-digit displays are also available.
Total Counter models are also Available.
Complies with UL and CSA Marking. Unit type: CS1 Special I/O Units.
Name: High speed Counter Units.
Specifications: Countable channels,
2; Encoder A and B inputs,
pulse input Z signals, Open collector,
Input voltage: 5VDC,12VDC, or 24VDC,
(up to 2 axes for 5 V or 12 V input),
RS-422 line driver;
Max. counting rate, 50kHz, 500kHz.
No. of unit numbers allocated: 4.
Current consumption: 5V, 0.45A; 26V, --.
Standards: UC, N, L, CE.
High-Speed, Flexible Control With A,
Wide Array of Features.
Equipped with 2 or 4 Counters and counts,
over a maximum binary range of 32-bits.
Accepting input pulse frequencies of up,
to 500 kHz allows precise control of fast motions.
The Unit is equipped with 4 Digital Inputs,
4 Digital Outputs and 28 Soft Outputs.
A maximum response time of 0.5 ms guarantees,
high-speed closed loop control of applications. Size: 48 x 96mm.
Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function.
Event entry point: 4.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.
S8EX-N03015 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=S8EX-N03015&select=5