Type: square.
Screen mode: no segmentation.
Output: SPDT.
Power supply voltage: DC12V.
Contact type: small load operation (AC125V, 0.1A; DC30V, 0.1A).
Operation: instantaneous action (auto reset).
Operation Department color: yellow.
In the touch and the ability to protect than OMRON''s previous models have improved.
The micro volume design of 23mm is realized.
Micro design and unique combination of soft sensing
S8JC-Z01512CD
LED has five colors (red, yellow, green, white, and blue).
Built in basic switch improves touch.
Built in basic switches in the previous model based on the OMRON to improve the protection.
Chip LED to produce a uniform surface brightness.
From the front panel installation, more convenient. E32-TC200 type: special beam type; long range / high function,
Specialty: M4 screw,
Shape / detection distance (mm): 4000; 4000; 2600 (1500),
Bending radius (mm): R25.
Standard test object (minimum test object) (mm) 1: 4 (0.1),
Fiber element for meeting diversified needsActuator: Roller lever (metal lever, resin roller).
Conduit size: 2-conduit; M20.
Built-in switch mechanism: 2NC/1NO MBB (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Internal I/O common: NPN.
I/O indicators: LED display (yellow).
Unit power supply current consumption:
80 mA max. (for 20.4 to 26.4-VDC power supply voltage)
Weight: 190 g max.
Expansion functions: No.
Short-circuit protection function: No.
High-speed digital I/O terminal with the,
screw type terminal block for EtherCAT,
communications.
Detachable screw terminal block facilitates,
the maintenance.
The expansion unit can be connected.
(One expansion unit per one I/O terminal unit.)
Input/output point can be flexibly increased,
depending on the system.
Input response time can be switched for,
high-speed processing.
Selectable node address setting methods:
setting with rotary switch and with tool software.
When setting the nodes with rotary switch,
setting is easy and node identification becomes,
possible for maintenance.
S8JC-Z01512CD Operation manual/Instructions/Model selection sample download link: