LK Automation Limited LK Automation Limited
Brand Sort: OMRON
Home >> Price
SGE-245-2-0360 00300C Pirce
No PHOTO
OMRON SGE-245-2-0360 00300C
Time specification: Instantaneous type.
Current setting range: 50 to 160 A.
Operating voltage: 400/440 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase SGE-245-2-0360 00300C
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Type: 1C contact type.
Shape: round.
Terminal shape: terminal for printed board.
Action: alternate.
Display mode: do not display.
Operation Department color: red.
Large capacity compact type push button switch.
Can also be used as a power switch with a large capacity cut.
Can be switched from micro load (minimum applicable load 1mA DC5V) to large capacity load. Output: DPDT.
Lighting: LED without Voltage Reduction Unit.
Operating voltage: 5 VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white.
Item: Alternate operation (Self-holding).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Detect errors in motors and other equipment,
through current changes.
Monitor for overcurrents and undercurrents,
simultaneously with one Relay.
Monitor AC or DC currents with one Relay.
Use with commercially available CTs (CT secondary side: 0 to 1 A or 0 to 5 A).
Width of 17.5 mm to reduce space required in panels.
Push-In Plus Terminal that reduce wiring work.
The use of cage clamps enables wiring with bare stranded wires.
Double-insertion holes for crossover wiring (all terminals).
UL listed for easy shipping to North America.
Models added with transistor outputs for superior contact reliability.
SGE-245-2-0360 00300C Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=SGE-245-2-0360 00300C&select=5


...more relevant model market price >>>>
Related products