Name: Safety Network Controllers.
No. of I/O points: Safety inputs, 12 *; Test outputs, 2; Safety outputs, 6.
Unit version: Ver. 1.0.
Safety inputs Test outputs Safety outputs
New Lineup for Safety Applications,
with Up to 12 Inputs.
Circuits for the required safety category are easy to build.
The safety circuits you create can be registered as templates,
and reused, for easy standardization
SGE-245-2-1360 01000C
A wide range of TÜV-certified templates is also available.
The NE0A operating conditions can be monitored from a,
standard DeviceNet Master.
Network distribution is possible by combining with an NE1A,
Safety Controller.
ISO13849-1 (PLe) and IEC 61508 SIL3 certification. Number of beams: 32.
Protective height: 670mm.
Model: PNP.
Easy-to-use Safety Sensor Ideal for.
Simple On/Off Detection Applications.
Provides simple safety functions - saving TCO.
by reducing errors.
Simple wiring with only 4 wires.
Fast response time of 5 ms. Ratings: Standard load; 4 A at 30 VDC.
Cable: VCTF cable *2.
Actuator: Sealed pin plunger.
Cable length : 3 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Appearance: Round/Projection type LED lighting,
(without Voltage Reduction Unit)A22L-T.
Output: SPST-NO + SPST-NO.
Lighting: LED.
Operating voltage: 12 VAC/VDC.
Operation: Alternate operation (self-holding).
Illumination color: R (red); Y (yellow); G (green); W (white); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring).
Lever for easily mounting and removing the Switch Unit.
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models).