Appearance: Square/Projection type A22-C.
Output: SPST-NO + SPST-NO.
Operation: Alternate operation (self-holding).
Illumination color: R (red); Y (yellow); G (green);
W (white); A (blue); B (black).
Install in 22-dia. or 25-dia. Panel Cutout.
(When Using a Ring).
Lever for easily mounting and removing the Switch Unit.
Increase wiring efficiency with three-row mounting of Switch Blocks.
Finger protection mechanism on Switch Unit provided as a standard feature
UMEC-10
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type.
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). Absolute diameter 65.
High resolution absolute type for detecting instrument and precision positioning.
To achieve a resolution of 12 bits (maximum 4096) of high resolution.
Response frequency is the high speed response of 40kHz
Output with gray code and BCD code.
The shape is smaller than the old one.
Power supply voltage: DC5 ~ 24V.
Output form: Gray 2.
Output code: open collector output. Appearance: High sound.
w/jumper direction A *2: Intermittent (short).
w/jumper direction B *2(w/o jumper): Intermittent (long).
Supply voltage: 12 to 24 VDC.
Buzzer Unit Series with Cylindrical.
22-mm × 16-dia. Body.
Lineup includes standard-volume models (80 phons, constant) and,
high-volume models (70 to 95 phons, variable). Intermittent or,
continuous sound can be selected. Case color: Black.
Control output: Relay output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 2.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
UMEC-10 Operation manual/Instructions/Model selection sample download link: