Type of input: AC current input.
Output type: communication; RS-485; NPN open collector (HH, H, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table
V-16-3C6
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
DeviNumber of beams: 207.
Protective height: 2080mm.
Model: NPN output.
Easy-to-use Safety Sensor Ideal for.
Simple On/Off Detection Applications.
Provides simple safety functions - saving TCO.
by reducing errors.
Simple wiring with only 4 wires.
Fast response time of 5 ms. Output: SPDT.
Lighting: LED without Voltage Reduction Unit.
Operating voltage: 24 VAC/VDC.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; PW: pure white.
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Rated voltage: 230 V .
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated current: 50 Hz, 0.040 A; 60 Hz, 0.040 A .
Rated input: 50 Hz, 7 W ; 60 Hz, 6 W .
Rated rotational speed: 50 Hz, 2200 r/min; 60 Hz, 2500 r/min.
Maximum flow rate: 50 Hz, 0.6 m3/min; 60 Hz, 0.7 m3/min.
Maximum static pressure: 50 Hz, 25.0 Pa; 60 Hz, 32.0 Pa.
Noise: 50 Hz, 26 dB; 60 Hz, 29 dB.
Optimum Cooling with a Comprehensive.
Lineup of Axial Fans.
Low noise level, long service life, and resistance to the,
environment.
Shaft supported by ball bearings for highly-reliable operation.
Plastic-bladed models (44 type) and metal-bladed models,
(28 type) included in series.
R87T-A@A15H-WR Water-resistant AC Axial Fans,
(IP X7 degree of protection) added to series.
CE marking compliant and certified by UL and CSA.
Note: The compliant standards and certified safety standards depend on the,
product. Check the information given for available models of Axial fans and,