Unit classification: CJ1 Special I/O Units.
Product name: Isolated type DC Input Units.
Input points: 2 inputs.
Signal range selection: DC voltage:
0 to 1.25 V, -1.25 to 1.25 V, 0 to 5 V,
1 to 5 V, -5 to 5 V, 0 to 10 V, -10 to 10 V,
±10 V selectable range DC current:
0 to 20 mA, 4 to 20 mA.
Conversion speed (resolution): Conversion,
speed: 10 ms/2 inputs, Resolution: 1/64,000 V700-HMD11 2M
Accuracy at ambient temperature of 25°C:
Accuracy: (±0.05% of F.S.
External connection: Removable terminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.18A; 24V, 0.09A.
Standards: UC1, CE.
A Single Unit Handling All Types of Inputs,
such as Temperature Sensor Inputs and,
Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5V).
A Unit supports four input channels,
each of which can be set to a
platinum resistance thermometer, thermocouple,
and DC signal (current, voltage).
All inputs are isolated. Actuator: Panel mount plunger.
Type: Micro load.
Compact, General-purpose Horizontal.
Switches.
Models for Microloads Added to Series.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.),
Incorporates a switch with a durable coil spring in a tough,
high precision case.
Compact and uses a single basic switch for applications where,
strength is required.
Models for microloads and models with operation indicators,
added to series.
Terminal protective cover can be switched to wire cable from,
either the left or right.
Sealing characteristics that meet IEC IP67 degree of protection. Appearance: Shielded, M30.
Sensing distance: 8 mm.
Output configuration: DC 3-wire, NPN.
Model: Operation mode, NO.
Chip-immune Inductive.
Proximity Sensor.
Correct operation even with aluminum or iron chips sticking,
to the Sensor.
Only the sensing object is detected.
Pre-wired Smartclick Connector Models also available. Size: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output.
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
V700-HMD11 2M Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=V700-HMD11 2M&select=5


...more relevant model market price >>>>
Related products
OMRON
Smart Fiber Amplifier Unit
E3X-HD11 2M
OMRON Smart Fiber Amplifier Unit E3X-HD11 2M
Connecting method: Pre-wired 2 m. Mod
OMRON
Digital optical fiber sensor
E3X-ZD11 2M
OMRON Digital optical fiber sensor E3X-ZD11 2M
Super fine tuning utton. Large size of