OMRON VRSF-3D-1000-T2
Specifications: I/O;
NPN (input: + common, output: - common);
Input: 8 points/Output: 8 points.
I/O connections: M3 Screw terminals.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Allows I/O Expansion with Transistor Terminals.
Wide variety of data, such as maintenance system data,
can be collected without affecting the productivity,
of the control system VRSF-3D-1000-T2
Valuable information can be collected,
and managed through the network, including information,
on the communications power supply.
voltage levels, Unit wear and tear,
and equipment operating information.
Expansion via Expansion I/O Units.
With no communications baud rate settings,
required and detachable terminal blocks,
maintenance is easier. Actuator: Plunger.
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 2NC/1NO (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Unit type: CJ1 Basic I/O Units.
Product name: Interrupt Input Unit.
Specifications: I/O points, 16 inputs;
Input voltage current, 24 VDC, 7mA;
Commons: 16 points, 1 common;
Input pulse widt conditions, ON time:
0.05 ms max. OFF time: 0.5 ms max;
Max. Units mountable per Unit, 2;
External connection, Removable terminal block.
No. of words allocated: 1 word.
Current consumption: 5V, 0.08A; 24V, --.
Standards: UC1, N, L, CE.
High-speed Starting of I/O InterruptTasks.
Use Up to Two Units for a Total of Up,
to 32 Interrupt Inputs.
Receive inputs to start I/O interrupt tasks.
When the Interrupt Input Unit receives an input,
the CPU Unit will interrupt execution of the,
cyclic tasks in the normal.
program and execute an I/O interrupt task.
VRSF-3D-1000-T2 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=VRSF-3D-1000-T2&select=5


...more relevant model market price >>>>
Related products