Cable length L: A, 1.5 m; B, 1.25 m.
Connect Connector-Terminal,
Block Conversion Units (XW2@) to,
I/O Units for Programmable,
Controllers with one touch. No. of notches: 2 notches.
Output: SPDT.
Reset method: Manual.
Lighting method: LED.
Separate Construction with Cylindrical.
16-dia. Body.
Same separate construction as the A16-series Pushbuttons with,
Miniature Design of 28.5 mm.
The same contacts can be used for both standard loads and,
microloads
WL01CA2
Oil-resistant IP65 models,
Conforms to EN60947-5-1. Case color: Black.
Control output: Relay output.
Control mode *1: Standard.
No. of auxiliary outputs: --.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, E5GN-RTC;
Resistance thermometer input, E5GN-RP.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. The main body: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
WL01CA2 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=WL01CA2&select=5