Appearance: 6.5 dia.
Sensing distance: 4 mm.
Connecting method: M8 Connector Models.
Cable specifications: --.
Operation mode: Nc.
Wire color /pin arrangement: 1: +V, 3: 0 V, 4: Control output.
Model: NPN output.
Ultra small size, but surprisingly easy installation!
With the addition of M4, 5.4-dia., 6.5-dia. size, unshielded,
pre-wired connector model, and connector model, a total of,
108 model variations are available
WLCA2-55LDK43
High-speed response frequency stably detects moving,
objects: 5 kHz max.
Four indicator lamps for easier indicator positioning.
Special mounting brackets reduce time and efforts for,
installation.
Protective Stainless-steel Spiral Tube against wire,
breakage is available (M4, M5 only).
Models also available with standard cables that are 5 m long,
or with robot (bending-resistant) cables. Sensing distance: (See note 2.)0 to 3.5 mm(pressed position) (See note 1.).
Sensing method: Pushbutton.
Operation mode: ON with no load.
Cable length: 1 m (robot cable).
Model: NPN output .
Using a pushbutton enables,
accurately detecting difficult-to-detec objects.
Conforms to standards for semiconductor FOUP cassettes to ena,
accurately detecting FOUP cassettes without being affected by the,
material, color, or reflectance of the bottoms of the cassettes.
Thin design enables mounting in a wider range of applications, e.g.,
on transfer arms.
Increased visibility with 4-direction indicator.
Optical detection of actuator operation provides a long life,
(mechanical life: 5 million operations min.).
Models available with PNP or NPN output.
Models are available with very flexible robot cable. Isolation method: Relay.
Zero cross function: No.
Operation indicator: Yes.
Applicable output load(See note.): 5 A 100 to 240 VAC.
Rated input voltage: 12 VDC.
Hybridization of a Magnetic Relay and an,
SSR Achieves 10-A Switching for 10 Million,
Operations.
UL/CSA certified (-VD models).
Using a triac to open and close the circuit reduces chattering,
and arching, thereby increasing the electrical durability to 10,
million operations.
Relays contacts for power ON and 10-A switching with high,
capacity are provided in a compact body without the need of,
radiators. Plus, there is almost no effect on heat generation,
or ambient temperature.
Operation indicators to easily check operation.
Built-in temperature fuse prevents internal burning due to,
triac or relay malfunctions.
Socket-type Relays the same size as the 1-pole and 2-pole,
LY Relays.
WLCA2-55LDK43 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=WLCA2-55LDK43&select=5