Time specification: Instantaneous type.
Current setting range: 8 to 26 A.
Operating voltage: 100/110/120 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase
WLGCA2-LD-N
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
before using the K2CM. Appearance: Knob-type Selector Switch A22S.
Number of notches: 3 notches.
Resetting method: Manual.
Output: SPST-NC + SPST-NC.
Color of Selector: Black.
Install in 22-dia. or 25-dia. Panel Cutout.
Lever for easily mounting and removing the Switch Unit.
Finger protection mechanism on Switch Unit provided as a standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type,
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). NO. OF I/O SLOTS: 8 SLOTSSensing method: Convergent reflective.
Connection method: Pre-wired (2 m).
Sensing distance : 20 to 35 mm .
function Timer: With .
Model: NPN output.
Reliable Detection Unaffected by PCB.
Holes or Notches.
High-limit E3S-LS3@ is suitable for incorporation in devices.
Wide-range E3S-LS3@W is ideal for detecting tall components,
mounted on boards.
Timer function models available. Type of input: AC voltage input.
Output type: BCD+ transistor; -; NPN open collector (5 bit output +HH, PASS, L, LL).
Event input terminal 5 points (TIMING, S-TIM, HOLD, RESET, ZERO) is equipped with.
External supply 80mA DC12V.
Power supply voltage: AC100 ~ 240V.
96 (W) * 48 (H * 95mm) depth
Some models are not equipped with.
The most suitable voltage and current signal simulation, measurement and display, identification of the panel table.
Action determine the color, can switch the green / Red 2 kinds of color display.
Equipped with the sub pressure gauge for monitoring the operation trend.
External event input can be applied to a variety of measurement and identification situations.
D
WLGCA2-LD-N Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=WLGCA2-LD-N&select=5