E32-D25XR type: standard type; soft (new standard),
Specialty: flat shape (small),
Bending radius (mm): R; R1.
Standard test object (minimum test object) (mm) 1: (0.005),
Fiber element for meeting diversified needsActuator: Adjustable roller lever, form lock (metal lever, resin roller).
Conduit size: 2-conduit; G1/2.
Built-in switch mechanism: 2NC (Slow-action).
A Series of Pull-reset Models Now
XG4S-2004
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC.
M12-connector models are available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC. Power supply: AC power supply.
Output method: Transistor output source type.
Inputs points: 12 points.
Outputs points: 8 points.Rated voltage: 115 V.
Permitted voltage fluctuation range: 85% to 110% rated voltage.
Frequency: 50/60 Hz.
Rated rotational speed: 50 Hz, 2100 r/min; 60 Hz, 2200 r/min.
Maximum flow rate: 50 Hz, 0.9 m3/min; 60 Hz, 1.0 m3/min.
Maximum static pressure: 50 Hz, 43 Pa; 60 Hz, 42 Pa.
Noise: 50 Hz, 42 dB; 60 Hz, 43 dB.
Weight: Approx. 1120 g.
Comprehensive Lineup of Single,
Double, and Triple Axial Fans with,
Easy One-step Mounting.
Mounts in a square cutout and conceals the hole-cut to,
simplify installation work.
Cover can be set to open either upward or downward for,
convenience in confined spaces.
Enhanced accessories (finger guard, filter, plug cord,
mounting screws).
Optional Replacement Filter and Vent Attachment.
The lineup includes Single, Double, and Triple Box Fans,
with eight models with plastic blades and eight models with,
metal blades. Control cycle: Yearly.
Number of outputs: 4 circuits.
Mounting method: Surface mounting/track mounting.
Supply voltage: 100 to 240 VAC.
Easier, More Convenient Time Switches, with,
New 4-circuit Output and Yearly Models in,
Addition to 2-circuit Weekly Models.
Independent Day Keys provide easier operation.
Temporary holiday setting function makes it easy to turn OFF,
output for holidays and non-operating days.
Settings can be made even with the Time Switch turned OFF.
Test mode enables easy program checking.
Complies with EMC Directives, UL/CSA, and other safety standards.
Includes summer time (DST) adjustment.
Yearly models also offer automatic switching to DST.
Set value can be changed both upward and downward for speedier setting.
Integrated temperature compensation circuit helps keep,
accurate time over a wide temperature range. (See note 1.)
Includes time counter and total counter functions with alarm,
indicator. (See note 2.)
Bank function allows program switching by an external input.
(See note 3.)
New 4-circuit output models with a compact, 72 × 72-mm DIN,
size added to the series.
XG4S-2004 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=XG4S-2004&select=5