No. of notches: 3 notches.
Output: DPDT.
Reset method: Manual.
Lighting method: LED.
Separate Construction with Cylindrical.
16-dia. Body.
Same separate construction as the A16-series Pushbuttons with,
Miniature Design of 28.5 mm.
The same contacts can be used for both standard loads and,
microloads.
Oil-resistant IP65 models,
Conforms to EN60947-5-1. Input / output: 32.
Pole number: 40
XS4W-D521-110-D
I/O: output.
Common mode terminal: YES.
Connector mounting type: XG4A-4031.
Cable connector type: XG4M-4030-T.
The use of non threaded terminals can greatly reduce the amount of plant wiring and the required hours.
The caliper terminal so that you can no longer without fastening screws.
Only insert the rod - shaped terminal to complete a touch type wiring. Sensing method: Diffuse-reflective.
Connection method: Pre-wired (2 m).
Sensing distance: 5 to 30 mm.
Operation mode: Dark-ON.
Model: NPN output.
Makes Mounting and Installation Simpler and Smoother.
Suitable for Applications in the Rechargeable Battery Industry. Contact type: Microload (125 VAC, 0.1 A; 30 VDC, 0.1 A).
Operation: Momentary operation (Self-resetting).
Case color: Black.
Output: DPDT.
Lighting: LED; 12 VDC.
Pushbutton color symbol: R.O.G.W.
Large Square-bodied Lighted.
Pushbutton Switches.
Excellent operating sensitivity.
Excellent illumination with even surface brightness.
Three-color models (green, orange, red; chameleon lighting).
included in lineup. Classification: High-capacity.
Contact gap: E (1.8 mm).
Actuator: Panel mount cross roller plunger.
Best-selling Basic Switch Boasting.
High Precision and Wide Variety.
A large switching capacity of 15 A with high repeat accuracy.
A wide range of variations in contact form for your selection: basic,
split-contact, maintained-contact, and adjustable contact gap types.
A series of standard models for micro loads is available.
A series of molded terminal-type models incorporating safety,
terminal protective cover is available. Unit type: CS1 Basic I/O Units.
Product name: Safety Relay Unit.
Specifications: Function, Emergency stop Unit;
Power supply voltage, 24 VDC;
Number of input words,
1 word or 2 words (Shared inputs);
Contact type (Safety output), DPSTNO;
Number of general inputs, 4 inputs/common;
Externa connections, Remov able terminal block.
Mountable Racks: CPU Rack, CS1W-BC,
@@3, Yes, @@2, Yes;
C200HX/HG/HE Expansion I/O Rack, No.
CS1 Expansion Rack, CS1W-BI,
@@3, Yes, @@2, Yes;
CS1 Long distance Expansion Rack, Yes;
SYSMAC BUS Slave Rack, No.
Words required: 1 word.
Current consumption: 5V system, 0.10A;
26 V system, --.
Standards: U, C, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control.
XS4W-D521-110-D Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=XS4W-D521-110-D&select=5