LK Automation Limited LK Automation Limited
Brand Sort: OMRON
Home >> Price
G2A-432AY DC100 Pirce
No PHOTO
OMRON G2A-432AY DC100
Classification: Standard.
Contact gap: G (0.5 mm).
Actuator: Short hinge lever.
Best-selling Basic Switch Boasting.
High Precision and Wide Variety.
A large switching capacity of 15 A with high repeat accuracy.
A wide range of variations in contact form for your selection: basic,
split-contact, maintained-contact, and adjustable contact gap types.
A series of standard models for micro loads is available G2A-432AY DC100
A series of molded terminal-type models incorporating safety,
terminal protective cover is available. Actuator: Roller lever (resin lever, bearing roller).
Conduit size: 1-conduit; M20.
Built-in switch mechanism: 2NC(Snap-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Unit type: CJ1 Basic I/O Units.
name: B7A Interface Units.
Specifications: I/O points, 64 outputs;
External connection, Removable terminal block.
No. of words allocated: 4 words.
Current consumption: 5V, 0.07A; 24V, --.
Standards: UC1, CE.
It transmits 16 points of I/O signals per,
word with a pair of cables.
Easy and minimized wiring effort,
The B7A Interface Unit and B7A Link Terminal,
can be used in the same way as a standard,
Basic I/O Unit and I/O Terminal without,
any need to worry about communications.
This characteristic reduces the wiring,
when using more than one relatively remote,
sensor or actuator.
Model: DSR (67S).
Protection of distributed power supply connection to power system,
The relay is smaller, and the protection unit is more enriched.
Waste heat generation system improve the comprehensive energy efficiency and the use of natural,
Energy of wind power generation, the spread of power is becoming more and more popular.
This relay is used to detect the internal fault of the user in the distributed power supply,
Power line accident of distributed power supply and relay protection system.
The relay can be meet in Japan (system connected instant points specified in the standard model),
Function, can be through more than 20 kinds of products to establish the best protection system.
Can also correspond to the generator and the electric side / internal tributaries.
Unit with 2 relay elements.
In each unit, the variable action time circuit is hidden, so that the coordination design is more convenient.
All aircraft equipped with a locking relay terminal.
DSR can correctly determine the direction of the sudden drop in the voltage to 0 of the short-circuit accident.
2 stage cross terminal stand with cover with convenient wiring.
G2A-432AY DC100 Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=G2A-432AY DC100&select=5


...more relevant model market price >>>>
Related products
OMRON
Power Relay
G2A-432AY
OMRON Power Relay G2A-432AY
Classification: Arc arrier equipped mod
OMRON
Power Relay
G2A-4321P
OMRON Power Relay G2A-4321P
Classification: Standard model. PCB ter
OMRON
Power Relay
G2A-432A-N1
OMRON Power Relay G2A-432A-N1
Classification: Built-in operation indic
OMRON
Power Relay
G2A-432A
OMRON Power Relay G2A-432A
Classification: Standard model. Plug-in