Global standard size, low profile slim.
I/O relay with width 6.2 mm.
Realized about 25% lower profile than conventional.
products, contributing to further miniaturization of the control panel.
Realized opening and closing ability with one pole 6 A slim shape.
Micro load products for one pole 50 mA using Au-plated.
contacts for small load switching also available.
Since G2RV is a transparent case, confirming the state of,
the contact with the naked eye is possible, and easy to,
confirm abnormality on-site (installed location)
G3F-203SLN-VD DC5
Screw terminal is also stocked to meet the screw type needs.
Mounted relay uses plug-in terminals that are difficult to,
bend when exchanging. Output: SPDT.
Lighting: Non-lighted.
Pushbutton colorsymbol: R: red, Y: yellow; PY: pure yellow
G: green, A: blue; W: white; B: black *2.
Item: Momentary operation (Self-resetting).
Separate Construction with.
Cylindrical 16-dia. Body.
Miniature design of 28.5 mm, the smallest class in the industry.
Detachable Switch.
The same contacts can be used for both standard loads and microloads.
Easy-to-wire terminal arrangement.
Certified for EN 60947-5-1. Number of phases: Single-phase.
Insulation method: Phototriac coupler.
Operation indicator: Yes (yellow).
Rated input voltage: 12 to 24 VDC.
Zero cross function: Yes.
Applicable load: 45 A, 200 to 480 VAC.
Compact, Slim-profile SSRs with Heat,
Sinks. Models with No Zero Cross for,
a Wide Range of Applications.
RoHS compliant.
Models also available with no zero cross,
Surge pass protection improved surge dielectric strength for,
output currents. (OMRON testing).
Compact with a slim profile.
Mount to DIN Track or with screws.
Conforms to UL, CSA, and EN standards (TÜV certification). Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-232C.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output.
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
G3F-203SLN-VD DC5 Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=G3F-203SLN-VD DC5&select=5