Type: rectangle.
Screen mode: no segmentation.
Output: DPDT.
Power supply voltage: DC5V.
Contact type: small load operation (AC125V, 0.1A; DC30V, 0.1A).
Operation: instantaneous action (auto reset).
Operation Department color: yellow.
In the touch and the ability to protect than OMRON''s previous models have improved.
The micro volume design of 23mm is realized.
Micro design and unique combination of soft sensing
H3CR-H8RL AC200-240 M
LED has five colors (red, yellow, green, white, and blue).
Built in basic switch improves touch.
Built in basic switches in the previous model based on the OMRON to improve the protection.
Chip LED to produce a uniform surface brightness.
From the front panel installation, more convenient. Power supply voltage: 100 to 240 VAC.
Heater control method: ON/OFF control SSR control.
Input specifications: Two current inputs,
(for either single phase or threephase).
Output specifications: One relay output.
Communications output: RS-485.
Current input range: 20.0 to 200.0 A.
A high-precision Heater Element.
Burnout Detector compatible with a,
wide-range of heater control methods.
Push-in terminals reduce the workload.
Scaling.
NPN or PNP equivalent output.
Lineup includes models compatible with many heater control methods,
including ON/OFF control, phase control, and cyclic control.
High-precision heater burnout alarm with digital measurement.
Contributes to preventative maintenance.
If the gate function is disabled, the gate input can be used as an,
undercurrent/overcurrent relay or for motor or lamp loads.
Undercurrent detection values can be set separately for CT1 and CT2.
CE marking and cUL certified (K8AC-H2@@@). CV500-VP CPU Bus Unit Personal Computer Unit Main Mem CV500-VP217.
8-MB memory; w/o floating-point processor.Ontology: terminal type, analog input type.
Category: control output 2 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output 1: voltage output (SSR driver).
Control output 2: voltage output (SSR driver)
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use.
Event input points: -.
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV state display function, convenient to view the thermostat