LK Automation Limited LK Automation Limited
Brand Sort: OMRON
Home >> Price
H3JA-8C AC100-120 3M Pirce
No PHOTO
OMRON H3JA-8C AC100-120 3M
Unit type: CJ1 Basic I/O Units.
Product name: Transistor Output Units.
Specifications: Output type, Sourcing;
I/O points, 32 outputs;
Maximum switching capacity, 24VDC,
0.5A Short-circuit protection;
Commons, 16 points, 1 common;
External connection, MIL connector.
No. of words allocated: 2 words.
Current consumption: 5V, 0.15A; 24V, --.
Standards: UC1, N, L, CE.
A Wide Range of Basic Output,
Units for High Speed Output,
and Different Applications H3JA-8C AC100-120 3M
These Output Units receive the ,
results of output instructions ,
from the CPU Unit and perform ON/OFF,
control for external devices.
High-speed Output models CJ1W-OD213 and,
CJ1W-OD234 can help to increase system.
throughput. Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: RS-485.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Outputs: Time-limit contact.
Supply voltage: 110 VAC (50/60 Hz); 220 VAC (50/60 Hz).
A wide star-time range (up to 120 seconds) and star-delta,
transfer time range (up to 1.0 seconds).
Setting rings (order separately) to enable consistent settings,
and to limit the setting range.
Panel Covers (order separately) to enable various panel designs.
Approved by UL, CSA, CE and CCC.
H3JA-8C AC100-120 3M Operation manual/Instructions/Model selection sample download link: /searchDownload.html?Search=H3JA-8C AC100-120 3M&select=5