Appearance: Knob-type Selector Switch A22W,
LED voltage-reduction lighting (without Voltage Reduction Unit).
Number of notches: 2 notches.
Resetting method: Automatic.
Output: SPST-NO + SPST-NO.
Operating voltage: 200 VAC.
Illumination color: R (red); Y (yellow); G (green); A (blue).
Install in 22-dia. or 25-dia. Panel Cutout.
Lever for easily mounting and removing the Switch Unit.
Finger protection mechanism on Switch Unit provided as a standard feature
H7CX-AW
Use 25-dia. ring to install in 25-dia. panel cutouts.
Mounted using either open-type (fork-type) or closed-type,
(round-type) crimp terminals.
IP65 oil resistance (non-lighted models).
IP65 (lighted models). The ultra small size, high performance and rich models.
5.5mm ultra small built-in amplifier.
Maximum detection distance 2.5mm. Workpiece shaking can also be stable detection.
Response frequency 1kHz.
Low consumption current.
Category: DC 3 wire type.
Shape: non shield.
Detection surface: below.
Detection range: 2.5mm.
Output form: NPN.
Action mode: NO. No. of notches: 2 notches.
Output: SPDT.
Reset method: Automatic.
Lighting method: LED.
Separate Construction with Cylindrical.
16-dia. Body.
Same separate construction as the A16-series Pushbuttons with,
Miniature Design of 28.5 mm.
The same contacts can be used for both standard loads and,
microloads.
Oil-resistant IP65 models,
Conforms to EN60947-5-1. Time specification: Inverse type.
Current setting range: 20 to 65 A.
Operating voltage: 200/220/240 VAC.
Resetting method: Manual.
Solid-state Relay Enables Choice of Three.
Operating Functions (Overcurrent, Open,
phase, and Reverse-phase).
Protects 3-phase induction motors and their loads from damage.
Selection and combination of operating functions from overcur,
rent, open-phase, and reverse-phase.
Circuit and output relay operation can be checked by just operat,
ing the test button.
The set time value can be checked easily because operation time,
is indicated from the start of operation.
Space-saving, integrated construction.
Note: If the K2CM is used with an inverter, the operating conditions will,
depend on the load wiring length, inverter carrier frequency, basic,
frequency, and load conditions. Error will occur in the operating,
values of the overload elements. It is recommended to test operation,
H7CX-AW Operation manual/Instructions/Model selection sample download link:
/searchDownload.html?Search=H7CX-AW&select=5