Specification: Thermocouple input (J/K),
ON/OFF or advanced PID control,
transistor (PNP) output, 2 loops.E3F3-D16 detection method: diffuse reflection type,
Lead extraction: CN M12,
Type: Plastic appearance; NPN output,
Threaded cylindrical photoelectric sensor, built-in amplifier,
Photoelectric sensor with proximity sensor appearance
High anti interference with optoelectronic -IC technologyActuator: Adjustable roller lever, form lock (metal lever, resin roller)
H7ER-NV-BH
Conduit size: 2-conduit; M20.
Built-in switch mechanism: 2NC (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Sensing method: Diffuse reflective.
Appearance: Vertical.
Connection method: Pre-wired .
Sensing distance: 35±3 mm.
Model: NPN Voltage output type .
Both Red-light Models and Green,
light Models to Detect a Wide Variety,
of Colors. Type: 1-Conduit (High pull-force type).
Contact configuration: Slow-action; 3NC.
Conduit opening/Connector: G1/2.
Multi-contact, Labor-saving,
Environment-friendly, Next,
generation Safety-door Switch.
Lineup includes three contact models with 2NC/1NO,
and 3NC contact forms and MBB models in addition,
to the previous contact forms 1NC/1NO, and 2NC.
M12-connector models are available, saving on,
labor and simplifying replacement.
Standardized gold-clad contacts provide high,
contact reliability.
Applicable to both standard loads and microloads.
Variety of metallic heads available. Case color: Black.
Control output: Current output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: 2.
Transfer output *2: Transfer output using control output.
Communi cations: --.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.
H7ER-NV-BH Operation manual/Instructions/Model selection sample download link: