Actuator: Plunger.
Conduit size: 1-conduit; Pg13.5.
Built-in switch mechanism: 2NC/1NO (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement
K3HB-XAA-BCD1 AC100-240
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. No. of steps: 6.
Rated voltage: 24 VDC, 100 VAC, 200 VAC.
Ideal for Controlling Pumps and Production.
Lines with Six or Twelve Stepping Circuits.
Built-in relays switch 2 A at 250 VAC or 30 VDC.
Initialization of stepping with reset input.
Uses memory that stores setting status for 10 days without.
power. All internal contacts are released when no power is supplied.
Detects an internal element malfunction caused by external.
noise, indicates the malfunction with an alarm indicator, and,
turns the relay alarm output ON. (An internal relay malfunction,
or internal relay contact weld cannot be detected.).
With safety-design terminals which prevent electric shock accidents.
With easy-to-see indicators which display the stepping status. Power supply voltage: DC24V.
Control output: PNP output. Sensor type: Transparent detected with P-opaquing function.
Sensing distance: 0.1 to 2 m with E39-RP1.
Connection method: M12 connector.
Model: PNP output.
A new generation in sensing performance.
Simplicity.
Simple selection.
Simple installation.
One family for all.
All standard applications covered.
A wide variety of models.
Models designed for special applications.
Non-stop detection.
High quality and reliability.
High EMC protection.
High light immunity.
Robust and waterproof housing. Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 1 dia.
Protective tubing length L: 20 cm.
Lead wire type: Standard.
Lead wire length M: 8m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal.